These 2 extra steps are shown in the following example.

To set the Under-Voltage Protection:

Step #

Do This

You Will See

1

PROT SET

OVP SET 0V

ALARMS

2

PROT SET

 

ALARMS

Press repeatedly until the

UVP SET 0V

desired setting appears.

 

3

ENTER

UVP SET 0V

 

 

 

 

 

4

Use the Voltage knob, the numeric

UVP SET ####V

keypad, or the arrow keys to enter a

 

value (0–103% of the unit’s rated

 

 

voltage).

 

5

ENTER

S/D if trip? N

 

 

 

 

 

6

Use the arrow keys to select Yes or

S/D if trip? Y

 

No. For this example, Yes is selected.

 

7

ENTER

This setting is saved and the display

 

 

returns to its default operating mode.

To set the Over-Current Protection:

Step #

Do This

You Will See

1

PROT SET

OVP SET 0V

ALARMS

2

PROT SET

 

ALARMS

Press repeatedly until the

OCP SET 0A

desired setting appears.

 

3

ENTER

OCP SET 0A

 

 

 

 

 

4

Use the Current knob, the numeric

OCP SET ####A

keypad, or the arrow keys to enter a

 

value (0–103% of the unit’s rated

 

 

current).

 

5

ENTER

S/D if trip? N

 

 

 

 

 

6

Use the arrow keys to select Yes or

S/D if trip? Y

 

No. For this example, Yes is selected.

 

7

ENTER

This setting is saved and the display

 

 

returns to its default operating mode.