Release 3.0

203

Table B.5Commands for Calibration

Function

SCPI Command

Description

Query

Restore Factory

[:]CALibration[<channel>]:RESTore

Restonres the calibration to the constants set

N/A

ion

 

at the factory

 

 

 

 

Change Calibration

[:]CALibration[<channel>][:SECure]:CODE <codeword>

Changes the calibration security code.

No

Password

 

 

 

Set Calibration State

[:]CALibration[<channel>][:SECure]:STATe

Change calibration state (mode)

Yes

 

<on-off-state>,<codeword>

 

 

Set Analog Current

[:]CALibration[<channel>]:ANALog:<5V10V>:PROGram:CURRe

Set analog programming current calibration

No

Programming Input Level

nt:LEVel {MINimumMAXimum}

level

 

Enter Analog Current

[:]CALibration[<channel>]:ANALog:

Set analog programming current calibration

No

Programming Input Data

:{5V10V}:PROGram:CURRent[:DATA] <current>

data

 

Set Analog Voltage

[:]CALibration[<channel>]:ANALog:

Set analog programming voltage calibration

No

Programming Input Level

:{5V10V}:PROGram:VOLTage:LEVel {MINimumMAXimum}

level

 

Enter Analog Voltage

[:]CALibration[<channel>]:ANALog:

Set analog programming voltage calibration

No

Programming Input Data

:{5V10V}:PROGram:VOLTage[:DATA] <current>

data

 

Set Analog Current

[:]CALibration[<channel>]:ANALog:

Set analog readback current calibration level

No

Readback Output Level

:{5V10V}:READback:CURRent:LEVel {MINimumMAXimum}

 

 

Enter Analog Current

[:]CALibration[<channel>]:ANALog:

Set analog readback current calibration data

No

Readback Output Data

:{5V10V}:READback:CURRent[:DATA] <current>

 

 

Set Analog Voltage

[:]CALibration[<channel>]:ANALog:

Set analog readback voltage calibration level

No

Readback Output Level

:{5V10V}:READback:VOLTage:LEVel {MINimumMAXimum}

 

 

Enter Analog Voltage

[:]CALibration[<channel>]:ANALog:

Set analog readback voltage calibration data

No

Readback Output Data

:{5V10V}:READback:VOLTage[:DATA] <current>

 

 

Set Supply Output Current

[:]CALibration[<channel>]:OUTPut:CURRent:LEVel

Set output current calibration level

No

Level

{MINimumMAXimum}

 

 

Enter Output Current Data

[:]CALibration[<channel>]:OUTPut:CURRent[:DATA]

Set output current calibration data

No

 

<current>

 

 

Set Supply Output Voltage

[:]CALibration[<channel>]:OUTPut:VOLTage:LEVel

Set voltage output calibration level

No

Level

{MINimumMAXimum}

 

 

Enter Output Voltage Data

[:]CALibration[<channel>]:OUTPut:VOLTage[:DATA]

Set voltage output calibration data

No

 

<voltage>

 

 

Table B.6Command to Clear all Protection Mechanisms

Function

SCPI Command

Description

Query

Clear Output Protection

[:]OUTPut[<channel>]:PROTection:CLEar

Clears the protection mechanism.

N/A

SCPI Command Reference

SCPI Command Summary

Page 205
Image 205
Xantrex Technology XDC manual Table B.5Commands for Calibration, Table B.6Command to Clear all Protection Mechanisms