Remote Operation

Remote Analog Operation

Using Connect your programming voltage sources and monitors, ensuring that the Remote appropriate 0– 5V or 0–10V range has been configured and selected. (See page 75.) Analog With the Analog Control mode selected, varying the programming source from 0 to Control 5V (or 10) will vary the output voltage or current from 0 to its rated maximum. A

voltage in the range of 0–5V (or 10) on the corresponding monitor line is proportional to 0–100% of the rated output.

The output V and I readback lines are active for all operating modes as are the user interface lines. The analog programming inputs are active only when selected using the procedure in “Select Remote Control Source” on page 75. You can select analog remote control or either the output voltage or current, or both. When only voltage or current is being remotely controlled, the other setpoint is under front panel local control.

112

Operating Manual for XDC Series Power Supply

Page 114
Image 114
Xantrex Technology XDC manual 112