Table B.3Commands for Output Control

Function

SCPI Command

Description

Query

Set (Immediate) Current

[[:]SOURce][<channel>]:CURRent[:LEVel][:IMMediate][:A

Change current setpoint

Yes

Setpoint

MPLitude] {<current>MAXimumMINimum}

 

 

Set Triggered Current

[[:]SOURce][<channel>]:CURRent[:LEVel]:TRIGgered[:AMP

Change triggered current setpoint

Yes

Setpoint

Litude] {<current>MAXimumMINimumDEFault}

 

 

Set (Immediate) Power

[[:]SOURce][<channel>]:POWer[:LEVel][:IMMediate][:AMP

Change power setpoint

Yes

Setpoint

Litude] {<power>MAXimumMINimum}

 

 

Set Triggered Power

[[:]SOURce][<channel>]:POWer[:LEVel]:TRIGgered[:AMPLi

Change triggered power setpoint

Yes

Setpoint

tude] {<power>MAXimumMINimumDEFault}

 

 

Set (Immediate)

[[:]SOURce][<channel>]:VOLTage[:LEVel][:IMMediate][:A

Change voltage setpoint

Yes

Voltage Setpoint

MPLitude] {<voltage>MAXimumMINimum}

 

 

Set Triggered Voltage

[[:]SOURce][<channel>]:VOLTage[:LEVel]:TRIGgered[:AMP

Change triggered votlage setpoint

Yes

Setpoint

Litude] {<voltage>MAXimumMINimumDEFault}

 

 

Set Voltage Slew Rate

[[:]SOURce][<channel>]:VOLTage:SLEW:STEP{<slewrate-vo

Sets the voltage slew rate voltage change

Yes

Voltage

ltage>MAXimumMINimumDEFault}

for the programmed time interval

 

Set Voltage Slew Rate

[[:]SOURce][<channel>]:VOLTage:SLEW:INTerval{<slewrat

Sets the voltage slew rate time interval for

Yes

Interval

e-interval>MAXimumMINimumDEFault}

the programmed voltage change

 

Set Over Current

[[:]SOURce][<channel>]:CURRent:PROTection[:OVER][:LEV

Set the over current protection level

Yes

Protection Level

el] {<current>MAXimumMINimum}

 

 

Set Over Current

[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]:STAT

Select over current protection to

Yes

Protection

e <on-off-state>

shutdown(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Over Current

[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]:TRIP

Query if over current protection mechanism

N/A

Protection Tripped

ped?

has tripped

 

Set Under Current

[[:]SOURce][<channel>]:CURRent:PROTection:UNDer[:LEVe

Set under current protection level

Yes

Protection Level

l] {<current>MAXimumMINimum}

 

 

Set Under Current

[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:STATe

Select under current protection to shutdown

Yes

Protection

<on-off-state>

(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Under Current

[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:TRIPp

Query if under current protection

N/A

Protection Tripped

ed?

mechanism has tripped

 

Set Over Power

[SOURce][<channel>]:POWer:PROTection[:OVER][:LEVel]

Set the over power protection level

Yes

Protection Level

{<power>MAXimumMINimum}

 

 

Set Over Power

[SOURce][<channel>]:POWer:PROTection[:OVER]:STATe

Select over power protection to shutdown

Yes

Protection

<on-off-state>

(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Over Power

[[:]SOURce][<channel>]:POWer:PROTection[:OVER]:TRIPpe

Query if over power protection mechanism

N/A

Protection Tripped

d?

has tripped

 

Set Under Power

[[:]SOURce][<channel>]:POWer:PROTection:UNDer[:LEVel]

Set under power protection level

Yes

Protection Level

{<power>MAXimumMINimum}

 

 