Operation

Power Supply Operation

Programming This option allows you to set up command programs for automated operation.

a Sequence To program a sequence:

Note In the following procedure, only change the default setpoints if required. Otherwise simply press ENTER to accept.

:

Step #

Do This

 

 

 

You Will See

1

MENU

 

 

 

ERROR MSGS

 

 

 

 

 

 

 

 

 

 

 

2

 

or

MENU

6 times

AUTO SEQ PGM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

ENTER

 

 

 

Sequence 1

 

 

 

 

 

 

 

 

 

 

4

 

or

 

. Use the scroll Sequence #

 

keys to select a sequence to work

 

 

with.

 

 

 

 

 

 

 

 

 

 

5

ENTER

 

 

 

Edit Sequence

 

 

 

 

 

 

 

 

 

6

ENTER

Edit mode is selected

Step 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

ENTER

 

 

 

Edit Step

 

 

 

 

 

 

 

 

 

8

ENTER

Enter the step voltage

S01 ####V

setpoint

 

 

 

 

 

 

 

 

 

 

9

ENTER

Enter the step current

S01 ####A

setpoint.

 

 

 

 

 

 

 

 

 

 

10

ENTER

Enter the step power.

S01 ####W

 

 

 

 

 

 

 

 

 

 

 

 

11

ENTER

Enter the step OVP

S01 ####V

level.

 

 

 

 

 

 

 

 

 

 

 

 

12

ENTER

 

 

 

Set Step Time

 

 

 

 

 

13 or . Use the scroll

keys to select how you want to advance to the next step:

Set Step Time waits for a certain period. See the “Setting step advance by time:” table below.

Wait for Trig waits for a trigger event. See the “Setting step advance by trigger:” table below.