Remote Operation

SCPI Commands for Digital Interfaces

Table 4.13 Remote CONtrol Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Analog

The Voltage Setpoint is under control of the

 

 

Control

Analog Programming Interface.

 

 

Voltage

 

1

2

Analog

The Current Setpoint is under control of the

 

 

Control

Analog Programming interface.

 

 

Current

 

2

4

GPIB

The power supply is under Remote CONtrol via

 

 

CONtrol

the GPIB interface.

3

8

GPIB

The power supply is under Remote Control via

 

 

CONtrol

the GPIB interface, with local controls locked out.

 

 

with LLO

 

4

16

RS-232

The power supply is under Remote CONtrol via

 

 

CONtrol

the RS-232 interface.

 

 

 

 

5

32

RS-232

The power supply is under Remote CONtTrol via

 

 

Control with

the RS-232 interface, with local controls locked

 

 

LLO

out.

 

 

 

 

6

64

Multi-chann

The power supply is under Remote CONtrol via

 

 

el CONtrol

the Multi-channel Programming interface.

7

128

Multi-chann

The power supply is under Remote CONtrol via

 

 

el Control

the Multi-channel Programming interface, with

 

 

with LLO

local controls locked out.

Current SHare Sub-Register

This register shows the state of the current share configuration, which can either be set through the front panel Current Share Config menu, or through the SCPI command SOURce:COMBine:CSHare:MODE.

Table 4.14 Current SHare Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

MASTer

The power supply is configured to be a Current

 

 

 

Share Master.

 

 

 

 

1

2

SLAVe

The power supply is configured to be a Current

 

 

 

Share Slave.

148