Error Messages

Current Share Error Codes

Current Share Error Codes

Current share functionality is only available with the 6000 Watt power supply.

Table C.13Current Share Error Codes

Error

Error Message Description

code

 

+1900

Current Share General Error

 

 

+1911

Current share master already online

 

A unit on the CANbus network has already been assigned the current share

 

master unit. Only one is allowed per network.

 

 

+1912

Current share slave lost

 

One of the connected current share slaves have not responded in time.

+1921

Current share master lost

 

The assigned master has not responded in time.

+1922

Current share slave connection refused

 

Connection as a slave on the current share network has been refused due to

 

one of the following reasons:

 

4 slaves are already online,

 

the voltage rating does not match those of the master’s,

 

the current rating does not match those of the master’s.

+1924

Current share data out of range

 

The voltage or current readback or setpoint values passed are out of range.

 

 

+1925

Current share slave output off by unknown

 

One of the slave’s output is off because of unknown reasons

+1926

Current share slave output off by command

 

One of the slave’s output is off because of a command from a remote source

 

or the front panel.

+1927

Current share slave output off by AC fail

 

One of the slave’s output is off because of an AC fail condition.

+1928

Current share slave output off by OTP (Over Temperature Protection)

 

One of the slave’s output is off because of an OTP condition.

 

 