Specifications and Characteristics

Electrical Specifications—Summary

Electrical Specifications—Summary

Table E.1Specifications for 6000 Watt units (10V to 60V Models)

Models

10-600

20-300

30-200

40-150

60-100

Output Ratings:

 

 

 

 

 

Output Voltage 1

0–10 V

0–20 V

0–30 V

0–40 V

0–60 V

Output Current 2

0–600 A

0–300 A

0–200 A

0–150 A

0–100 A

Output Power

6000 W

6000 W

6000 W

6000 W

6000 W

Line Regulation: 3

 

 

 

 

 

Voltage (0.01% of Vmax)

1 mV

2 mV

3 mV

4 mV

6 mV

Current (0.05% of Imax)

300 mA

150 mA

100 mA

75 mA

50 mA

Load Regulation: 4

 

 

 

 

 

Voltage (0.05% of Vmax + 5 mV)

10 mV

15 mV

20 mV

25 mV

35 mV

Current (0.1% of Imax + 20 mA)

620 mA

320 mA

220 mA

170 mA

120 mA

Meter Accuracy:

 

 

 

 

 

Voltage (0.15% of Vmax)

15 mV

30 mV

45 mV

60 mV

90 mV

Current (0.5% of Imax)

3 A

1.5 A

1.0 A

750 mA

500 mA

Output Noise (0–20 MHz):

 

 

 

 

 

Voltage (p–p)

75 mV

75 mV

75 mV

75 mV

100 mV

Output Ripple (rms):

 

 

 

 

 

Voltage

10 mV

10 mV

12 mV

15 mV

15 mV

Current 5

3100 mA

1600 mA

1000 mA

750 mA

450 mA

OVP Adjustment Range:

 

 

 

 

 

(0% to 103% of Vmax)

0–10.3 V

0–20.6 V

0–30.9 V

0–41.2 V

0–61.8 V

Efficiency: 6

0.85

0.87

0.87

0.87

0.89

1.Minimum output voltage is <0.3% of rated voltage at zero output setting.

2.Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.

3.For input voltage variation over the AC input voltage range, with constant rated load.

4.For 0–100% load variation, with constant nominal line voltage.

5.Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.

6.Typical efficiency at nominal input voltage and full output power.

228

Operating Manual for XDC Series Power Supply

Page 230
Image 230
Xantrex Technology XDC manual Electrical Specifications-Summary, Specifications and Characteristics