Remote Operation

GPIB Operation

Configuration Configure the power supply’s GPIB address and power-on service request setting. The defaults are GPIB address 2 and power-on service request off.

Front panel

First set the GPIB parameters:

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

5 times

REMOTE CONFIG

3

ENTER

RS-232 Cfg

 

 

 

 

 

 

2 times

GPIB Cfg

4

ENTER

GPIB Addr ##

 

 

 

 

 

5

Select an address from 1-30

GPIB Addr 2

6

ENTER

PON SRQ? Y

 

 

 

7

or

Options are

Y (Yes) or

 

Select whether power-on service

 

N (No)

 

request is to be sent.

 

8

ENTER

Settings are saved.

 

 

 

 

Next, select GPIB as the remote control interface.

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

4 times

REMOTE SELECT

3

ENTER

RS-232

 

 

 

 

 

4

or

GPIB

 

Select GPIB.

 

 

 

 

5

ENTER

GPIB setting is saved.

 

 

 

 