Operation

Power Supply Operation

To set both OTP and AC Off to Auto-Recovery:

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

3 times1

S/D RECOVERY

3

ENTER

OTP Latched2

4

 

OTP AutoRecov

5 ENTER

ACO AutoRecov3

OTP is set to Auto Recovery.

6

ENTER

ACO remains set to Auto Recovery and the display returns to its default operating mode.

1.You can also press MENU 4 times to bring up the Shutdown Recovery option.

2.The default is Latched. You can leave it at Latched or change it to Auto-Recovery. Press either arrow key repeatedly until the desired option appears.

3.The default is AutoRecov. You can leave it at Auto-Recovery or change it to Latched. Press either arrow key repeatedly until the desired option appears.

Respond to If there is a protection alarm, press the PROT SET/ALARMS key to read the Alarms message or messages. Once you have read a message, the system clears it from

memory. To tell the system that a message has been read, press an arrow key. If a message has been read and the conditions that caused the alarm no longer exist, the display shows Alarms Cleared.

If the unit has shut down, resume operation by pressing the OUT ON/OFF key.

The following table shows what to do if there is an OC Alarm and an OP Alarm, and the conditions that caused the alarms no longer exist:

Step #

Do This

You Will See

1

PROT SET

OC Alarm

ALARMS

2

 

OP Alarm

72

Operating Manual for XDC Series Power Supply

Page 74
Image 74