Operation
Power Supply Operation
72 Operating Manual for XDC Series Power Supply
To set both OTP and AC Off to Auto-Recovery:
Respond to
Alarms
If there is a protection alarm, press the PROT SET/ALARMS key to read the
message or messages. Once you have read a message, the system clears it from
memory. To tell the system that a message has been read, press an arrow key. If a
message has been read and the conditions that caused the alarm no longer exist, the
display shows Alarms Cleared.
If the unit has shut down, resume operation by pressing the OUT ON/OFF key.
The following table shows what to do if there is an OC Alarm and an OP Alarm, and
the conditions that caused the alarms no longer exist:
Step # Do This You Will See
1ERROR MSGS
2 3 times1
1. You can also press MENU 4 times to bring up the Shutdown Recovery option.
S/D RECOVERY
3 OTP Latched2
2. The default is Latched. You can leave it at Latched or change it to Auto-Recovery. Press
either arrow key repeatedly until the desired option appears.
4OTP AutoRecov
5ACO AutoRecov3
OTP is set to Auto Recovery.
3. The default is AutoRecov. You can leave it at Auto-Recovery or change it to Latched. Press
either arrow key repeatedly until the desired option appears.
6
ACO remains set to Auto Recovery
and the display returns to its default
operating mode.
MENU
ENTER
ENTER
ENTER
Step # Do This You Will See
1OC Alarm
2OP Alarm
PROT SET
ALARMS