Remote Operation

SCPI Commands for Digital Interfaces

Temperature Sub-Register Commands

Query Questionable Temperature Sub-Register Event

Temperature Event Sub-Register is read and then cleared.

SCPI command: STATus[<channel>]:QUEStionable:TEMPerature[:EVENt]?

Query Questionable Temperature Sub-Register Condition

SCPI command:

STATus[<channel>]:QUEStionable:TEMPerature:CONDition?

Enable Temperature Sub-Register

SCPI command: STATus[<channel>]:QUEStionable:TEMPerature:ENABle <status-enable>

Query Format:

STATus[<channel>]:QUEStionable:TEMPerature:ENABle?

Set Temperature Positive Transition Filter

SCPI command: STATus[<channel>]:QUEStionable:TEMPerature:PTRansition <status-enable>

Query Format:

STATus[<channel>]:QUEStionable:TEMPerature:PTRansition?

Set Temperature Negative Transition Filter

SCPI command: STATus[<channel>]:QUEStionable:TEMPerature:NTRansition <status-enable>

Query Format:

STATus[<channel>]:QUEStionable:TEMPerature:NTRansition?