Operation
Power Supply Operating States
58 Operating Manual for XDC Series Power Supply
Powering
OFF the
Power Supply
From the front panel, the safest method for shutting down the power supply is:
Power Supply Operating States
The power supply has 5 operating states:
Power-On
Output Shutdown
Soft Start
Normal Operation
Calibration
Power-On This is the period between the time that AC power is applied to the supply (AC
breaker turned on) and the time that the power supply is ready for operation. During
this period, the internal circuits are powering up and performing self-tests. At the end
of the Power-On period, the supply is normally in its default Power-On mode with
the output OFF, VSET=0 and ISET=0.
Output
Shutdown
In this state, the output is disabled and there is no output regardless of power settings.
The power supply can be placed in the Output Shutdown state by a command (via
the front panel or from the programming interface), via the Interlock signal, or from
a protection mechanism. This is also called the Standby mode.
Soft Start In this state, the output power is ramping up gradually towards its target load. This
reduces equipment stress. This state occurs whenever the supply output is set to ON
or a protection state is re-set, and is approximately 2 seconds in duration.
Normal
Operation
This is the normal operating state for the power supply. The power supply is ready
to accept commands.
Calibration This is a service mode that is used to calibrate setpoints and readback levels for
accuracy. Calibration should only be performed by qualified service personnel. For
detailed information, see Appendix A.
Step # Do This You Will See
1The OUT OFF annunciator
illuminates; Ouput V and I are 0.
2Switch the AC power to OFF. The AC OFF alarm, and then the unit
fades to black.
OFF
ON
OUT