Remote Operation

SCPI Commands for Digital Interfaces

Selecting a Trigger Source

If any triggers are programmed into the sequence, select a trigger source:

PROG:TRIG:SOUR {BUSMANEXTIMM}

BUS - trigger signal is IEEE 488.1 GET or *TRG

MANual - trigger input is from the front panel TRIGGER key

EXTernal - The external trigger line is selected as the source.

IMMediate - The source is the SCPI command “INIT:IMM”

Editing Step Parameters

Commands are provided to edit only one of voltage, current, power, OVP level, step duration, or end action.

Program step voltage: PROG:STEP<step_number>:VOLT <voltage>

Program step current: PROG:STEP<step_number>:CURR <current>

Program step power: PROG:STEP<step_number>:POW <power>

Program step OVP level: PROG:STEP<step_number>:OVP <OVPlevel>

Program step time (duration): PROG:STEP<step_number>:DWEL {<time>TRIG}

To delete a step:

PROGram:STEP<step_number>:DELete

An error will result if the last step with the end action is deleted, without a new end action programmed to take its place.

Deleting Sequences

If you no longer need a sequence, select it with the PROG:NAME command and then delete it with the following:

PROGram:DELete

You can also use the following to delete all sequences:

PROGram:DELete:ALL

Release 3.0

139

Page 141
Image 141
Xantrex Technology XDC manual You can also use the following to delete all sequences, Selecting a Trigger Source