Xantrex Technology XDC manual Configure Remote Control Source

Models: XDC

1 254
Download 254 pages 27.31 Kb
Page 78
Image 78

Operation

Power Supply Operation

Configure

Remote

Control

Source

The REMOTE CONFIG menu option lets you set up the attributes of the remote control sources.

The following table shows how to access and work with the Remote Configuration option.

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

5 times1

REMOTE CONFIG

3

ENTER

RS-232 Cfg

 

 

 

 

 

4

or

RS-232 Cfg

 

Press repeatedly until the desired

Analog Cfg

 

GPIB Cfg

 

remote control source appears.

Multichnl Cfg

5

ENTER

See the tables that follow to see how

to proceed.

 

 

1. You can also press MENU 5 times.

After you have selected the remote control source you want to configure, configure that setting using appropriate values from the following table. Select values using the arrow keys or the numeric keypad. To save a value you have selected, press ENTER.

See Section 4, “Remote Operation” for detailed instructions on setting up remote interfaces.

Remote Control

Prompt

Configuration Settings

Source

 

 

RS-232

Baud ######

1200, 2400, 4800, 9600, 19200,

 

 

384001

 

Flow Ctl ####

Hdwr, XON, None2

Analog

Input #### V

Select the operating range of the

 

 

API:

 

 

0–5

 

 

0–10

GPIB

GPIB Addr ##

1–30

 

PON SRQ? Y

Y, N

Multichannel

Slave Addr ##

2-50

 

Connect?

Y, N

1.This range depends on the user’s network configuration.

2.Hdwr = hardware handshake; XON = software flow control XON/XOFF characters used; None = no flow control

76

Operating Manual for XDC Series Power Supply

Page 78
Image 78
Xantrex Technology XDC manual Configure Remote Control Source, Remote Control Prompt Configuration Settings Source