Operation
Power Supply Operation
76 Operating Manual for XDC Series Power Supply
Configure
Remote
Control
Source
The REMOTE CONFIG menu option lets you set up the attributes of the remote
control sources.
The following table shows how to access and work with the Remote Configuration
option.
After you have selected the remote control source you want to configure, configure
that setting using appropriate values from the following table. Select values using the
arrow keys or the numeric keypad. To save a value you have selected, press ENTER.
See Section 4, “Remote Operation” for detailed instructions on setting up remote
interfaces.
Step # Do This You Will See
1ERROR MSGS
2 5 times1
1. You can also press MENU 5 times.
REMOTE CONFIG
3 RS-232 Cfg
4 or
Press repeatedly until the desired
remote control source appears.
RS-232 Cfg
Analog Cfg
GPIB Cfg
Multichnl Cfg
5See the tables that follow to see how
to proceed.
Remote Control
Source Prompt Configuration Settings
RS-232 Baud ######
Flow Ctl ####
1200, 2400, 4800, 9600, 19200,
384001
Hdwr, XON, None2
1. This range depends on the user’s network configuration.
2. Hdwr = hardware handshake; XON = software flow control XON/XOFF characters used; None
= no flow control
Analog Input #### V Select the operating range of the
API:
0–5
0–10
GPIB GPIB Addr ##
PON SRQ? Y
1–30
Y, N
Multichannel Slave Addr ##
Connect?
2-50
Y, N
MENU
ENTER
ENTER