Select

Remote

Control

Source

Operation

Power Supply Operation

The REMOTE SELECT menu option allows you to select an interface for remote control. Before selecting a remote control source, be sure to set up each interface using the Remote Configure menu. See “Configure Remote Control Source” on page 76

Remote control sources are listed here along with their respective programming interfaces:

RS–232

Analog V & I: Voltage and current programmed via the analog interface

Analog V: Voltage programmed via the analog interface; current programmed via front panel

Analog I: Current programmed via the analog interface; voltage programmed via front panel

GPIB

Multichnl: multichannel operation using the optional CANbus interface between units (only available for 6000 Watt units)

To change the remote control source:

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

4 times

REMOTE SELECT

3

ENTER

RS-232

 

 

 

 

 

4

or

The options are RS-232, Analog V &

 

 

I, Analog V, Analog I, GPIB, and RMT

 

Press repeatedly until the desired

linked.

 

remote control source appears.

 

5

ENTER

The setting is saved and the display

returns to its default operating mode.

 

 

If you change the remote setting to GPIB, the next time you shift from local to remote control, the unit will shift to GPIB control.