Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 131
Under-Current Protection
To set the Under-Current Protection level:
SOUR:CURR:PROT:UND <current>
SOUR:CURR:PROT:UND:STAT <on-off-state>
The first UCP protection command sets the protection level. The second command
lets you choose a warning alarm only [OFF] or shut down with an alarm [ON] if the
protection level is exceeded.
To check the Under-Current Protection level:
SOUR:CURR:PROT?
To check if the Under-Current Protection was tripped:
SOUR:CURR:PROT:TRIP?
Over-Power Protection
To set the Over-Power Protection level:
SOUR:POW:PROT <wattage>
SOUR:POW:PROT:STAT <on-off-state>
The first OPP protection command sets the protection level. The second command
lets you choose a warning alarm only [OFF] or shut down with an alarm [ON] if the
protection level is exceeded.
To check the Over-Power Protection level:
SOUR:POW:PROT?
To check if the Over-Power Protection was tripped:
SOUR:POW:PROT:TRIP?
Under-Power Protection
To set the Under-Power Protection level:
SOUR:POW:PROT:UND <wattage>
SOUR:POW:PROT:UND:STAT <on-off-state>
The first UPP protection command sets the protection level. The second command
lets you choose a warning alarm only [OFF] or shut down with an alarm [ON] if the
protection level is exceeded.
To check the Under-Power Protection level:
SOUR:POW:PROT?
To check if the Under-Power Protection was tripped:
SOUR:POW:PROT:TRIP?