About The XDC Power Supply

Status Annunciators

1.AUX A: Condition selected for auxiliary line A is TRUE.

2.Master: Power supply is selected to be the master in current share configurations.

3.AUX B: Condition selected for auxiliary line B is TRUE.

4.Slave: Power supply is selected to act as a slave in current share configurations.

5.AUTO: Power supply is in auto sequence operation.

6.Pause: Auto sequence program is paused. (Output is still on.) Press RUN/PAUSE key to continue.

7.SEQ: Power supply is in auto sequence setup mode (if Set is also turned on) or in auto sequence operation.

8.Trigger?: Auto sequence program is waiting for a trigger signal to continue execution.

9.ERR: An error has occurred.

10.Set: Setting or setpoint is to be entered.

11.ADR: Power supply is being addressed (receiving data). (All remote digital interfaces.)

12.LCL: Power supply is under local (front panel) control.

13.SRQ: Service request. GPIB only.

14.RMT: Power supply is under remote control.

15.ALARM: Power supply is operating outside the parameters the user set by using PROT SET, or the power supply’s internal temperature has exceeded an internally set trip point (OTP).

16.OUT OFF: Power supply output is disabled; all other circuits are active; unit is in standby mode.

17.OVP: Power supply has exceeded an over-voltage trip point.

18.Interlock: Signals that the external shutdown line (the safety interlock line) has been activated, disabling the supply output.

19.OTP: Power supply has exceeded an over-temperature trip point, disabling the supply output.

20.OUT ON: Output is on.

21.Bar graphs: Graphical representation of output voltage, current, and power.

22.CV, CC, CP: Power supply is in constant voltage mode, constant current mode, or constant power mode.

Release 3.0

29

Page 31
Image 31
Xantrex Technology XDC manual Status Annunciators