Xantrex Technology XDC manual Typical Programming Resolution, Typical Measurement Resolution

Models: XDC

1 254
Download 254 pages 27.31 Kb
Page 240
Image 240

Specifications and Characteristics

Output Performance Specifications

Typical Programming Resolution

Front Panel or Remote Digital Interface

Voltage

0.002% of Vmax

Current

0.002% of Imax

Power

0.05% of Pmax

Over Voltage Protection

0.002% of Vmax

Remote Analog Programming Interface

Voltage

0.002% of Vmax

Current

0.002% of Imax

Typical Measurement Resolution

Front Panel or Remote Digital Interface

Voltage

0.002% of Vmax

Current

0.002% of Imax

Power

0.05% of Pmax

Remote Analog Programming Interface

Voltage

0.002% of Vmax

Current

0.002% of Imax

Programming Accuracy1

Front Panel or Remote Digital Interface

Voltage Programming

0.1% of Vmax

Current Programming

0.5% of Imax

Power Programming

0.5% of Pmax

Over voltage

0.1% of Vmax

Programming

 

Remote Analog Programming Interface

Voltage Programming

0.2% of Vmax

Current Programming

0.5% of Imax

Readback Accuracy

Front Panel or Remote Digital Interface

Voltage Readback

0.15% of Vmax

Current Readback

0.5% of Imax

Power Readback

0.5% of Pmax

Remote Analog Programming Interface

Voltage Readback

0.3% of Vmax

 

Current Readback

0.5% of Imax

 

 

 

 

 

1. Accuracy specifications apply for settings in range of 1% to 100% of rated output

238

Operating Manual for XDC Series Power Supply

Page 240
Image 240
Xantrex Technology XDC manual Typical Programming Resolution, Typical Measurement Resolution, Programming Accuracy1