Remote Operation

Remote Analog Operation

Next select analog programming as the remote control interface.

Your options are

Analog V & I - voltage and current programmed via the analog interface

Analog V - voltage programmed via the analog interface; current set via front panel

Analog I - current programmed via the analog interface; voltage set via front panel

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

4 times

REMOTE SELECT

3

ENTER

RS-232

 

 

 

 

 

4

or

Analog V&I,

 

Select desired option.

Analog V, or

 

Analog I

5

ENTER

Setting is saved.

 

 

 

 

Press the LCL/RMT button to begin remote operation via the analog interface.

SCPI

To select which setpoints to control via analog programming lines, use the command:

SYST:REM:SOUR {AVOLACURAVC}

Where

AVOL (Analog VOLtage) selects only voltage to be programmed via the analog programming lines

ACUR (Analog CURrent) selects only current to be programmed via the analog programming lines

AVC (Analog Voltage and Current) selects voltage and current to be programmed via the analog programming lines

To select the voltage level:

SYST:COMM:APR:LEV {510}

Where

“5” is the 0-5V range, and “10” is the 0-10V range

To put the unit into remote control:

SYST:REM:STAT REM

Release 3.0

111

Page 113
Image 113
Xantrex Technology XDC manual To select the voltage level, Where Is the 0-5V range, and 10 is the 0-10V range