Operation
Power Supply Operation
Release 3.0 69
To set the Under-Current Protection:To set the Over-Power Protection:
Step # Do This You Will See
1OVP SET 0V
2 Press repeatedly until the
desired setting appears.
UCP SET 0A
3UCP SET 0A
4Use the Current knob, the numeric
keypad, or the arrow keys to enter a
value. The value must be between
0–103% of the unit’s rated current.
UCP SET ####A
5S/D if trip? N
6Use the arrow keys to select Yes or No.
For this example, Yes is selected. S/D if trip? Y
7This setting is saved and the display
returns to its default operating mode.
Step # Do This You Will See
1OVP SET 0V
2 Press repeatedly until the
desired setting appears.
OPP SET 0W
3OPP SET 0W
4Use both the Current and Voltage
knobs, or the numeric keypad, or the
arrow keys to enter a value. The
value must be between 0W and
103% of the unit’s rated power.
OPP SET ####W
5S/D if trip? N
6Use the arrow keys to select Yes or
No. For this example, Yes is selected.
S/D if trip? Y
7This setting is saved and the display
returns to its default operating mode.
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER