202

Operating Manual for XDC Series Power Supply

Set Under Power

[[:]SOURce][<channel>]:POWer:PROTection:UNDer:STATe

Select under power protection to shutdown

Yes

Protection

<on-off-state>

(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Under Power

[[:]SOURce][<channel>]:POWer:PROTection:UNDer:TRIPped

Query if under power protection mechanism

N/A

Protection Tripped

?

has tripped

 

Set Over Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection[:OVER][:LEV

Set the over voltage protection level

Yes

Protection Level

el] {<voltage>MAXimumMINimum}

 

 

Query Over Voltage

[SOURce][<channel>]:VOLTage:PROTection[:OVER]:TRIPped

Query if over voltage protection mechanism

N/A

Protection Tripped

?

has tripped

 

Set Under Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection:UNDer[:LEVe

Set under voltage protection level

N/A

Protection Level

l] {<voltage>MAXimumMINimum}

 

 

Set Under Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection:UNDer:STATe

Select under voltage protection to shutdown

Yes

Protection

<on-off-state>

(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Under Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection:UNDer:TRIPp

Query if under voltage protection

N/A

Protection Tripped

ed?

mechanism has tripped

 

Set High Current Limit

[[:]SOURce][<channel>]:CURRent:LIMit:HIGH

Set upper limit of current setpoint range (soft

Yes

 

{<current>MAXimumMINimum}

limits)

 

Set Low Current Limit

[[:]SOURce][<channel>]:CURRent:LIMit:LOW

Set lower limit of current setpoint range (soft

Yes

 

{<current>MAXimumMINimum}

limits)

 

Set High Power Limit

[[:]SOURce][<channel>]:POWer:LIMit:HIGH

Set upper limit of power setpoint range (soft

Yes

 

{<power>MAXimumMINimum}

limits)

 

Set Low Power Limit

[[:]SOURce][<channel>]:POWer:LIMit:LOW

Set lower limit of power setpoint range (soft

Yes

 

{<power>MAXimumMINimum}

limits)

 

Set High Voltage Limit

[[:]SOURce][<channel>]:VOLTage:LIMit:HIGH

Set upper limit of voltage setpoint range

Yes

 

{<voltage>MAXimumMINimum}

(soft limits)

 

Set Low Voltage Limit

[[:]SOURce][<channel>]:VOLTage:LIMit:LOW

Set lower limit of voltage setpoint range (soft

Yes

 

{<voltage>MAXimumMINimum}

limits)

 

Table B.4Commands for Current Share (6000 W only)

Function

SCPI Command

Description

Query

Set Current Sharing Mode

[[:]SOURce][<channel>]:COMBine:CSHare:MODE

Select current share mode

Yes

 

{NONEMASTerSLAVe}

 

 

Read Summed Current

[:]MEASure[:SCALar]:CURRent[:DC]? SUM

Read total current output of all current

N/A

 

 

sharing supplies

 

SCPI Command Reference

SCPI Command Summary

Page 204
Image 204
Xantrex Technology XDC manual Table B.4Commands for Current Share 6000 W only, 202