Operation

Power Supply Operation

Auto-Sequence

Auto Sequence lets you recall a stored program next time the unit is powered on. (Assumes at least one program has been saved in memory. See “To edit the sequence’s trigger source:Using Auto Sequencing” on page 96.)

To select Auto Sequence:

Step # Do This

 

 

You Will See

1

MENU

 

 

ERROR MSGS

 

 

 

 

 

 

 

 

 

2

 

1

.

PON CONFIG

MENU

2 times

 

 

 

 

 

 

 

 

 

3

ENTER

 

 

Last Setting

 

 

 

 

 

 

 

 

 

4

 

2

.

Auto Sequence

MENU

3 times

 

 

 

 

 

 

 

 

 

5

ENTER

 

 

Auto Seq 1

 

 

 

 

 

 

 

 

 

6

 

or

to scroll3,

The default display for the selected

 

ENTER

to select.

operating mode.

 

 

1.You can also press the Down arrow 2 times.

2.You can also press the Down arrow 3 times.

3.You can scroll through up to 10 stored programs.

Program The AUTO SEQ PGM menu option is used to set up command programs for Auto automated operation. There are 10 programmable sequences with up to 99 steps per

Sequence sequence.

Each sequence can be repeated a programmable number of times or forever. If the sequence contains steps that advance by a trigger event, a single trigger source can be selected to advance those steps.

Each step can be programmed to set the voltage setpoint, current setpoint, power setoint, and OVP level automatically. Each step can also be programmed to advance by a delayed time or a trigger event. The duration of each step may range from 10 ms to 99 hours.