Operation

Power Supply Operation

Configure The USER LINES menu option lets you configure the auxiliary status lines User Lines The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor

the status of the power supply. The auxiliary lines are referred to as AUX A and AUX B. See “Making Connections for Remote Control” on page 107 for details. Each user line also has a corresponding annunciator on the front panel display to indicate when it is on. Aux lines can be set up to report the following status conditions:

None

Unregul: Output Unregulated

OVP: Over-Voltage Condition

UV: Under-Voltage Condition

OC: Over-Current Condition

UC: Under-Current Condition

OP: Over-Power Condition

UP: Under-Power Condition

AC Off: Input power has failed or is out of range

OTP: Over-Temperature Condition

Hi Temp: High-Temperature Condition

SenseProt: Sense Protection Tripped

Fold Prot: Fold Protection Tripped

CC: Constant Current Mode

CV: Constant Voltage Mode

CP: Constant Power Mode

Out ON: Output On

Out OFF: Output Off

To access and work with the USER LINES menu option:

Step #

Do This

You Will See

1

MENU

ERROR MSGS

 

 

 

 

 

2

1

USER LINES

 

3

ENTER

Aux line A

 

 

 

 

 

4

or

to select which Aux line B

 

line to configure.

 

 

 

 

5

ENTER

Cfg None

1. You can also press MENU again to bring up the AUX LINES option.

Release 3.0

83

Page 85
Image 85