Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 147
Protection SHUTdown Sub-Register
Table 4.12Protection SHUTdown Sub-Re gister
Remote CONtrol Sub-Register
This identifies which remote interface is controlling the unit. Only one bit is active
at a time with the exception of analog control, where voltage or current alone, or both
may be under remote control. Current share mode is considered to be under local
control, even though the user cannot adjust the voltage setting from the front panel.
Bit Bit Weight Bit Name Description
0 1 Over VOLTage Over voltage protection has tripped
1 2 Under VOLTage Under voltage protection has tripped
2 4 Over CURrent Over current protection has tripped
3 8 Under CURrent Under current protection has tripped
4 16 Over POWer Over power protection has tripped
5 32 Under POWer Under power protection has tripped
6 64 AC Off AC Off protection has tripped
7 128 Over TEMPerature Over temperature protection has tripped
8 256 SENSe Sense protection has tripped
9 512 FOLDback Foldback protection has tripped