Operation

Power Supply Operation

To set the Over-Voltage Protection:

Step #

Do This

You Will See

1

PROT SET

OVP SHUTDOWN

ALARMS

2

ENTER

OVP SET 0V

 

 

 

 

 

3

Use the Voltage knob, the numeric,

OVP SET ####V

keypad, or the arrow keys to enter a

 

value. The value must be between

 

 

0–103% of the unit’s rated voltage.

 

4

ENTER

This setting is saved and the display

 

 

returns to its default operating mode.

The other protection options follow a similar procedure, but have 2 extra steps:

1.When you press PROT SET / ALARMS, the OVP prompt appears. Press PROT SET/ ALARMS repeatedly to cycle through the other protection options.

2.Protection options, other than OVP, prompt you with S/D if trip? N Use the arrow keys to select Yes or No.

Yes shuts down the power supply if the protection limit is reached.

No issues a warning (a message in the Alarms menu) without shutting down the supply.