Specifications and Characteristics

Electrical Specifications—Summary

Table E.8Drift Specifications for 12000 Watt units (80V to 600V Models)

Models

80–150

100–120

150–80

300–40

600–20

Drift (30 minutes): 1

 

 

 

 

 

Voltage (0.04% of Vmax)

32 mV

40 mV

60 mV

120 mV

240 mV

Current (0.6% of Imax)

900 mA

720 mA

480 mA

240 mA

120 mA

 

 

 

 

 

 

Drift (8 hours): 2

 

 

 

 

 

Voltage (0.02% of Vmax)

16 mV

20 mV

30 mV

60 mV

120 mV

Current (0.05% of Imax)3

75 mA

60 mA

40 mA

20 mA

16 mA

Temperature Coefficient: 4

 

 

 

 

 

Voltage (0.04% of Vmax/°C)

32 mV

40 mV

60 mV

120 mV

240 mV

Current (0.06% of Imax/°C)

90 mA

72 mA

48 mA

24 mA

12 mA

1.Maximum drift over 30 minutes with constant line, load, and temperature, after power on.

2.Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.

3.Current drift for 600V-20A unit is 0.08% of Imax.

4.Change in output per °C change in ambient temperature, with constant line and load.

Release 3.0

235

Page 237
Image 237
Xantrex Technology XDC manual 235