200 Operating Manual for XDC Series Power Supply
SCPI Command Reference
SCPI Command Summary
Table B.2 Readback Commands
Save Default Settings *SDS
[:]SYSTem[<channel>]:SAVE:DEFault <setting_location>
Save the factory default settings. N/A
Query Service Request
Enable
*SRE?
[:]STATus[<channel>]:SREQuest:ENABle?
Query the Service Request Enable Register
bits.
N/A
Service Request Enable *SRE
[:]STATus[<channel>]:SREQuest:ENABle <status-enable>
Set the Service Request Enable Register
bits.
N/A
Read Status Byte *STB?
[:]STATus[<channel>]:SBYTe[EVENt]?
Read the status byte and Master Summary
Status bit.
N/A
Trigger *TRG Trigger commands. Analogous to the IEEE
488.1 defined Group Execute Trigger
interface message. See IEEE 488.2 section
6.1.4.2.5
N/A
Self-Test Query *TST?
[:]SYSTem[<channel>]:TEST?
Internal self-test and responds indicating
whether or not the device completed the
self-test without any detected errors.
N/A
Wait To Continue *WAI
[:]SYSTem[<channel>]:WAIT
Prevents the device from executing any
further commands or queries until the
no-operation-pending flag is TRUE.(*OPC?)
N/A
Function SCPI Command Description Query
Read Output Current [:]MEASure[<channel>][:SCALar]:CURRent[:DC]? Read output current N/A
Read Output Power [:]MEASure[<channel>][:SCALar]:POWer[:DC]? Read output power N/A
Read Output Voltage [:]MEASure[<channel>][:SCALar][:VOLTage][:DC]? Read output voltage N/A