Chapter 3: AT Commands Reference

Example

ATE?

001 OK

X, Result Code Selection and Call Progress Monitoring Control

This command defines the CONNECT result code format. It determines whether or not the

G24-L transmits particular result codes to the user. It also controls whether the G24-L verifies the presence of dial tone when it first goes off-hook to begin dialing, and whether the engaged tone (busy signal) detection is enabled.

 

 

 

 

Command Type

Syntax

Response/Action

Remarks

 

 

 

 

 

 

 

 

Set

ATX<value>

OK

The Set command sets the result code

 

 

or:

and call progress monitoring control.

 

 

+CME ERROR: <err>

 

 

 

 

 

Read

ATX?

<current value>

 

 

 

 

 

Test

 

 

The Test command for X is not defined

 

 

 

by ITU, and therefore is not supported

 

 

 

by the G24-L. The G24-L returns an

 

 

 

error.

 

 

 

 

 

 

 

 

The following table shows the X parameters.

 

 

Table 3-130: X Parameters

 

 

 

<Parameter>

 

Description

 

 

 

 

 

 

<value>

0

CONNECT result code given upon entering online data state:

 

 

Dial tone detection - Disabled

 

 

Busy detection - Disabled

 

1

CONNECT <text> result code given upon entering online data state:

 

 

Dial tone detection - Disabled

 

 

Busy detection - Disabled

 

2

CONNECT <text> result code given upon entering online data state:

 

 

Dial tone detection - Enabled

 

 

Busy detection - Disabled

 

3

CONNECT <text> result code given upon entering online data state:

 

 

Dial tone detection - Disabled

 

 

Busy detection - Enabled

 

4

CONNECT <text> result code given upon entering online data state:

 

 

Dial tone detection - Enabled

 

 

Busy detection - Enabled

 

The default value is 0.

 

 

 

 

 

 

Example

ATX?

000 OK