Call Control

+CACM, Accumulated Call Meter

This command resets the Advice of Charge accumulated call meter value in the SIM file, EFACM. ACM contains the total number of home units for both the current call and preceding calls.

 

 

 

 

Command

Syntax

Response/Action

Remarks

Type

 

 

 

 

 

 

 

 

 

 

 

Set

+CACM=<passwd>

OK

The Set command resets the

 

 

+CME ERROR: <err>

accumulated call meter value. SIM

 

 

 

PIN2 is required.

Read

+CACM?

+CACM: <acm>

The Read command displays the

 

 

+CME ERROR: <err>

current value of ACM.

 

 

 

 

Test

+CACM=?

OK

The Test command indicates whether

 

 

 

the +CACM command is functioning.

 

 

 

 

 

 

 

 

The following table shows the +CACM parameters.

 

Table 3-22: +CACM Parameters

 

 

<Parameter>

Description

 

 

 

 

<passwd>

SIM PIN2 password

 

Maximum string length is 8 characters. If this value is exceeded, the command

 

terminates in an error. If PIN2 is incorrect, "+CME ERROR: incorrect password" is

 

displayed.

 

 

<acm>

Accumulated call meter maximum value (similar to CCM; Refer to “+CAOC, Advice

 

of Charge”, page 3-44). The default is 0.

 

<ccm>

 

String type; three bytes of the current call meter value in hexadecimal format (for

 

example, 00001E indicates a decimal value of 30). Value is given in home units; bytes

 

are similarly coded as the ACMmax value in the SIM.

 

 

 

 

Example

AT+CACM=?

OK AT+CACM? +CACM:"000000"

OK AT+CACM="2222"

OK