Chapter 3: AT Commands Reference

OK AT+MADIGITAL=0

OK AT+MADIGITAL? +MADIGITAL: 0 OK AT+MADIGITAL=3

ERROR AT+MADIGITAL? +MADIGITAL: 0 OK

+CALM, Alert Sound Mode

This command handles the selection of the G24-L's alert sound mode. The value of the command is saved after a power cycle.

 

 

 

 

Command Type

Syntax

Response/Action

Remarks

 

 

 

 

 

 

 

 

Set

+CALM=<mode>

OK

The Set command sets the alert sound

 

 

+CME ERROR: <err>

mode.

 

 

 

 

Read

+CALM?

+CALM: <mode>

The Read command displays the

 

 

+CME ERROR: <err>

current alert sound mode setting.

 

 

 

 

Test

+CALM=?

+CALM: (list of

The Test command displays the list of

 

 

supported <mode>s)

supported modes.

 

 

+CME ERROR: <err>

 

 

 

 

 

 

 

 

 

The following table shows the +CALM parameters.

 

 

Table 3-113: +CALM Parameters

 

 

 

<Parameter>

 

Description

 

 

 

 

<mode>

Alert sound mode of the G24-L.

 

0

Ring (default)

 

1

Silent mode (ring prevented)

 

 

 

 

 

 

Note: Selecting the ring mode with this command retrieves the current alert volume level setting.

Example

AT+CALM=? +CALM: (0,1)

OK AT+CALM? +CALM: 0

OK AT+CALM=1

OK

April 15, 2008