Chapter 3: AT Commands Reference

The following table shows the +MBC parameters.

 

 

Table 3-82: +MBC Parameters

 

 

 

<Parameter>

 

Description

 

 

 

 

 

 

<Mode>

0

Stop battery charging.

 

1

Start battery charging.

 

2

Automatic battery charging.

 

 

 

<Ind>

0

Disable MBC unsolicited report (default).

 

1

Enable MBC unsolicited report.

 

 

 

<BatteryLevel>

0-5

Battery Level values (see Table 3-83).

 

 

<Status>

The status of the battery charger:

 

0

The battery is in charging process.

 

1

The battery is not in charging process.

 

 

 

 

 

 

The following table shows the battery levels parameters (as defined in +CBC command.

Table 3-83: Battery Level Parameters

 

 

 

VCC, V

 

Battery Level

 

 

 

 

 

 

>3.7

5

(90%)

 

 

 

3.5-3.7

4

(60%)

 

 

 

3.4-3.5

3

(20%)

 

 

 

3.35-3.4

2

(10%)

 

 

 

3.3-3.35

1

(5%)

 

 

 

<3.3

0

(0%)

 

 

 

 

 

 

Example

AT+MBC?

//Read the current values.

+MBC: 0,3,2,0

 

OK

 

AT+MBC=1,1

// Start charging with unsolicited report.

OK

 

AT+MBC?

//Read the current values.

+MBC: 0,3,1,1

 

OK

 

+MBC: 0,3,1,1

//Unsolicited reports

+MBC: 0,4,1,1

 

+MBC: 0,5,1,1

 

AT+MBC=?

//Test Mode.

+MBC: (0-2), (0-1)

 

OK

 

April 15, 2008

G24-L AT Commands Reference Manual

3-131

Page 195
Image 195
PIONEERPOS G24-LC manual 82 +MBC Parameters, Battery Level Parameters, Ind, BatteryLevel