Call Control

 

 

 

 

Command

Syntax

Response/Action

Remarks

Type

 

 

 

 

 

 

 

 

 

 

 

Read

AT+CBST?

+CBST:

 

 

 

<speed>,<name>,<ce>

 

 

 

OK

 

 

 

 

 

Test

AT+CBST=?

+CBST: (list of

The Test command returns values

 

 

supported

supported by the MA as compound

 

 

<speed>s),(list of

values.

 

 

supported

 

 

 

<name>s),(list of

 

 

 

supported <ce>s)

 

 

 

OK

 

 

 

 

 

 

 

 

 

The following table shows the +CBST parameters.

 

 

Table 3-14: +CBST Parameters

 

 

 

<Parameter>

 

Description

 

 

 

 

<speed>

0 - Auto-bauding (automatic selection of the speed; this setting is possible in case of

 

3.1 kHz modem and non-transparent service)

 

6 - 4800 bps (V.32)

 

7 - 9600 bps (V.32)

 

14

- 14400 bps (V.34)

 

68

- 2400 bps (V.110 or X.31 flag stuffing)

 

70

- 4800 bps (V.110 or X.31 flag stuffing)

 

71

- 9600 bps (V.110 or X.31 flag stuffing)

 

75

- 14400 bps (V.110 or X.31 flag stuffing)

 

The default value is 7.

 

Note: Currently the G24-L supports:

 

 

2 baud rates: 4800 and 9600 bps

 

 

2 protocols: V.110 and V.32

 

 

<name>

0 - Data circuit asynchronous (UDI or 3.1 kHz modem)

 

1 - Data circuit synchronous (UDI or 3.1 kHz modem)

 

The default value is 0.

 

 

<ce>

0 - Transparent (Reserved for future implementation)

 

1 - Non-transparent (default)

 

 

 

 

 

 

Example

AT+CBST=?

+CBST: (000,004,006,007,014,068,070,071,075),(000-001),(000-003)

OK AT+CBST? +CBST: 007,000,001

OK AT+CBST=6

OK AT+CBST? +CBST: 006,000,001

OK

3-32

G24-L AT Commands Reference Manual

April 15, 2008

Page 96
Image 96
PIONEERPOS G24-LC manual 14 +CBST Parameters, Parameter Description Speed, Name