SMS

Table 3-64: Layout of SMS-SUBMIT in PDU Mode: (according to GSM03.40)

 

 

 

 

Reference

 

Description

Length

 

 

 

 

 

 

<sca>

Service Center address:

1, 3-12 BYTES

 

1 BYTE: length (number of followed

(When length is 1, length BYTE = 0 )

 

octets).

Mandatory

 

 

1 BYTE: <tosca> - value between

 

 

128-255

 

 

 

 

 

<fo>

First Octet. See the table below.

1 BYTE

 

 

 

<TP-MR>

Message Reference. An integer

1 BYTE

 

representation of a reference number of

 

 

the SM submitted to the SC by the MS.

 

 

Values between 0-255.

 

 

 

 

<TP-DA>

Destination address formatted according

2-12 BYTES

 

to the formatting rules of address fields.

 

 

 

 

<TP-PID>

Protocol-Identifier. Values between

1 BYTE

 

0-255.

 

 

 

 

 

<TP-DCS>

Data Coding Scheme. Values between

1 BYTE

 

0-255.

 

 

 

 

 

<TP-VP>

Validity Period. depending on <fo>,

0, 1, 7 BYTE

 

TP-Validity-Period-Format bits setting.

 

 

 

 

<TP-UDL>

User data length

1 BYTE

 

 

 

 

<TP-UD>

User data

 

0-140 BYTES

 

 

 

 

 

 

 

 

Table 3-65: Layout of SMS-COMMAND in PDU Mode: (according to GSM03.40)

 

 

 

 

 

 

Reference

 

Description

Length

 

 

 

 

 

 

 

 

 

<sca>

Service Center address:

1, 3-12 BYTES

 

 

1 BYTE: length (number of followed

(When length is 1, length BYTE = 0 )

 

 

octets).

Mandatory

 

 

 

1 BYTE: <tosca> - value between

 

 

 

128-255

 

 

 

 

 

 

 

<fo>

First Octet. See Table 3-66.

1 BYTE

 

 

 

 

 

<TP-MR>

Message Reference. An integer

1 BYTE

 

 

representation of a reference number of

 

 

 

the SM submitted to the SC by the MS.

 

 

 

Values between 0-255.

 

 

 

 

 

 

<TP-PID>

Protocol-Identifier. Values between

1 BYTE

 

 

0-255.

 

 

 

 

 

 

 

<TP-CT>

Command Type

1 BYTE

 

 

 

 

 

<TP-MN>

Message Number

1 BYTE

 

 

 

 

 

<TP-DA>

Destination address formatted according

2-12 BYTES

 

 

to the formatting rules of address fields.

 

 

 

 

 

 

3-104

G24-L AT Commands Reference Manual

April 15, 2008

Page 168
Image 168
PIONEERPOS G24-LC manual Layout of SMS-SUBMIT in PDU Mode according to GSM03.40