PIONEERPOS G24-LC manual 98 +MMAD Parameters

Models: G24-LC G24-L

1 444
Download 444 pages 51.67 Kb
Page 215
Image 215

Chapter 3: AT Commands Reference

 

 

 

 

Command

 

 

 

Type

Syntax

Response/Action

Remarks

 

 

 

 

 

 

 

 

Unsolicited

AT+MMAD=<Conver

 

If <Report> value is - 3,

Messages

ter_number>

 

the report will be generated

 

 

 

according to report interval

 

 

 

value. If <Report interval>

 

Case:

 

value was not set, there

 

 

will be no messages, but

 

*. Average calculation

 

you can ask for a solicited

 

isn't active :

+MMAD:

message.

 

 

 

 

 

<Converter_number>,

 

 

 

<Converted_Value> OK

 

 

*. Average calculation

 

 

 

is active:

+MMAD:

 

 

 

 

 

 

<Converter_number>, <Average>

 

 

 

OK

 

 

 

 

 

 

 

 

 

The following table shows the +MMAD parameters.

Table 3-98: +MMAD Parameters

<Parameter>

 

Description

Range/Remark

 

 

 

 

 

 

<Converter

1-5Select the A2D converter.

 

Number>

 

 

 

 

 

 

 

<Report>

0

Unsolicited report is not active/ stop unsolicited report &

Optional for Average

 

deactivate +MMAD operation.

calculation.

 

1

Unsolicited report in active for all A2D conversion events.

 

 

2

Unsolicited reports are active only for out off boundaries events.

 

 

3

"Average report" - send periodic average.

 

 

 

 

<Rate>

1-255Select the time interval between two samples.

100mili - for average;

 

Units:

sec-Otherwise.

 

100 milli Sec - in case of average computation.

Mandatory for Average

 

Seconds - in case of A/D sampling only.

calculation.

 

 

 

<low>,<High>

0,230 or 300,450 A decimal value represents the digital value.

 

 

Low - The lowest boundary level of digital value.

 

 

High - The Highest boundary level of digital value.

 

 

Default value for converters 1-3 is 0,230.

 

 

Default value for converter 5 is 300,450.

 

 

 

 

<Converted

A decimal value represents the returned digital value.

 

Value>

For converters 1-3 and 5, the returned value represent the input level

 

 

multiplied by 100.

 

 

 

 

 

<Num_of_sam

2

- 255 The number of samples that are used for average calculation.

Mandatory for Average

ples>

 

 

calculation.

 

 

 

 

<Average_calc

1

- 255 For how long the average calculation will be active.

1- Default value if average is

_duration>

0

- Not active.

active.

 

255 - Endless.

While not active = 0.

 

1...254 - minutes.

 

 

 

 

 

April 15, 2008

G24-L AT Commands Reference Manual

3-151

Page 215
Image 215
PIONEERPOS G24-LC manual 98 +MMAD Parameters