PIONEERPOS G24-LC manual Layout of SMS-STATUS-REPORT in PDU Mode according to, Tp-Dt, Tp-St, Tp-Pi

Models: G24-LC G24-L

1 444
Download 444 pages 51.67 Kb
Page 162
Image 162

SMS

Table 3-58: Layout of SMS-STATUS-REPORT in PDU Mode (according to

 

GSM03.40) (Cont.)

 

 

 

Reference

Description

Length

 

 

 

 

 

 

<TP-RA>

Mandatory:

2-12 BYTES

 

Recipient address formatted according to

 

 

the formatting rules of address fields.

 

 

 

 

<TP-SCTS>

Mandatory:

7 BYTE

 

The TP-Service-Center-Time-Stamp field

 

 

is given in semi-octet representation, and

 

 

represents the local time as described in

 

 

GSM03.40

 

 

 

 

<TP-DT>

Mandatory:

7 BYTES

 

Discharge-Time of <TP-ST>, is given in

 

 

semioctet representation, and represents

 

 

the local time as described in GSM03.40

 

 

 

 

<TP-ST>

Mandatory:

1 BYTE

 

Status of the MO message

 

 

 

 

<TP-PI>

Optional:

1 BYTE

 

Parameter indicating the presence of any

 

 

of the optional parameters which follow.

 

 

See Table 3-59.

 

 

 

 

<TP-PID>

Optional:

1 BYTE

 

Protocol-Identifier. Values between

 

 

0-255.

 

 

 

 

<TP-DCS>

Optional:

1 BYTE

 

Data Coding Scheme. Values between

 

 

0-255.

 

 

 

 

<TP-UDL>

Optional:

1 BYTE

 

User data length

 

 

 

 

<TP-UD>

Optional:

131 BYTES

 

User data

 

 

 

 

 

 

 

Notes: Any unused bits will be set to zero by the sending entity and will be ignored by the receiving entity.

The maximum guaranteed length of TP-UD is 131 octets. In order to achieve the maximum octet of 143, the TP-RA field must have a length of two octets and TP-PID and TP-DCS must not be present.

TP-PI is Mandatory if any of the optional parameters following TP-PI is present, otherwise optional.