SMS

Table 3-67: <fo> for SMS-COMMAND Message

 

 

 

 

Bit/s

Reference

 

Description

 

 

 

 

 

 

0-1

Message-Type-Indicator

Parameter describing the message type.

 

 

1

0 SMS-COMMAND (in the direction

 

 

MS to SC)

 

 

 

5

TP-Status-Report-Request

Parameter indicating if a status report is

 

 

requested by the MS

 

 

0

A status report is not requested

 

 

1

A status report is requested

 

 

 

6

TP-User-Data-Header-Indicator

Parameter indicating whether the

 

 

beginning of the User Data field contains

 

 

a Header in addition to the short message

 

 

or contains only the short message

 

 

0

The TP-UD field contains only the

 

 

short message

 

 

1

The beginning of the TP-UD field

 

 

contains a Header in addition to the short

 

 

message

 

 

 

 

 

 

 

 

Note: Any unused bits will be set to 0.

Example

AT+CMGF=1

OK AT+CMGW="5124335432"

>This is the message body <CTRL+Z>//<CTRL+Z> ends the prompt text mode and returns to regular AT command mode

+CMGW: 126

OK AT+CMGW

>TEST <CTRL+Z> +CMGW: 195

OK AT+CMGF=0

OK AT+CMGW=24 >079179521201009511FF0B917962543940F20008001400410042004300440045 <CTRL+Z> +CMGW: 128

OK AT+CMGR=128 +CMGR: 2,,24 079179521201009511FF0B917962543940F20008001400410042004300440045

OK AT+CMGF=1

OK AT+CSDH=1

OK AT+CMGR=128

+CMGR: "STO UNSENT", "+97264593042",,145,17,0,8,0,"+972521100059",145,5

3-106

G24-L AT Commands Reference Manual

April 15, 2008

Page 170
Image 170
PIONEERPOS G24-LC manual fo for SMS-COMMAND Message, Ok At+Cmgw, OK AT+CMGF=1 OK AT+CSDH=1 OK AT+CMGR=128