MAX PRO-SERIES Communication/Configuration Specifications

1. OVERVIEW

The M7500-PRO has a RS232 interface that allows it to communicate with a wide variety of equipment as well as enable custom operating configurations to be programmed into the unit.

The purpose of this document is to outline the command set used to communicate with the M7500-PRO.

Commands and responses are in the form of ASCII character strings terminated with ASCII 13, line feed (ASCII 10) or NULL (ASCIØ).

2. PORT SETTINGS

Baud Rate:

 

 

 

 

 

9600bps

 

 

 

 

 

 

Data Bits:

 

 

 

 

 

 

8

 

 

 

 

 

Start Bits:

 

 

 

 

1

 

Stop Bits:

 

 

 

1

 

 

 

 

Flow Control:

 

 

None

 

 

Null modem cable not required.

DB9 Pinout Diagram

5

4

3

2

1

6

7

 

8

9

PIN NO.

 

SIGNAL

 

1

 

 

-

 

2

RECEIVE DATA

3

TRNSMIT DATA

4

 

 

-

 

5

GROUND

 

6

 

 

-

 

7

 

 

-

 

8

 

 

-

 

9

 

 

-

 

COMMANDS

The following are commands that can be made to the M7500-PRO.

<CR> = Carriage Return (Enter Button)

 

 

 

 

 

 

 

Command String

Action

 

Response

 

1.1

!BUTTON_ON<CR>

Changes the status of the front panel button to ON.

$BUTTON = ON<CR>

 

 

 

 

Has the same effect as if someone pressed the front

 

 

 

 

 

panel button for 2 seconds.

 

 

 

 

 

 

 

 

1.2

!BUTTON_OFF<CR>

Changes the status of the front panel button to OFF.

$BUTTON = OFF<CR>

 

 

 

 

Has the same effect as if someone pressed the front

 

 

 

 

 

panel button for 2 seconds.

 

 

 

 

 

 

 

 

1.3

!ALL_OFF<CR>

Turns off all outlets including those designated as

$BUTTON = OFF<CR>

 

 

 

 

always on. Turn off is immediate with no delay.

 

 

 

 

 

Terminates any running turn on or turn off sequence.

 

 

 

 

 

Overrides the DC trigger input.

 

 

 

 

 

Changes the status of the front panel button to OFF.

 

 

 

 

 

 

 

 

1.4

!ALL_ON<CR>

Turns on all outlets. Turn on is immediate with no delay.

If successful:

$BUTTON = ON<CR>

 

 

 

Terminates any running turn on or turn off sequence.

If over-voltage fault: $PWR = OVERVOLTAGE<CR>

 

 

 

Overrides the DC trigger input.

 

 

 

Changes the status of the front panel button to ON.

If under-voltage fault: $PWR = UNDERVOLTAGE<CR>

 

 

 

 

 

1.5

!SWITCH bank state<CR>

Turns a specific outlet bank or the trigger output on or

If bank or state are invalid, $INVALID_PARAMETER<CR>

 

 

bank = {1, 2, 3, 4, HC1, HC2,

off. Switching is immediate with no delay.

If bank and state are valid, and no fault exists, a

 

 

 

 

 

 

TRIGOUT}

 

 

confirmation message is sent. Refer to §3.1

 

 

state = {ON, OFF}

 

 

If over-voltage fault:$PWR = OVERVOLTAGE<CR>

 

 

Example: !SWITCH 2 ON<CR>

 

 

 

 

(turns on outlet bank 2)

 

 

If under-voltage fault: $PWR = UNDERVOLTAGE<CR>

 

 

 

 

 

 

 

 

 

 

 

 

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

 

9

Page 11
Image 11
Panamax 7500-PRO owner manual Command String Action Response, Switch bank stateCR, Trigout

7500-PRO specifications

The Panamax 7500-PRO is a highly regarded power management system designed to safeguard electronic devices from electrical disturbances. This model is known for its robust performance and exceptional features that cater to both home and professional environments.

One of the standout characteristics of the Panamax 7500-PRO is its advanced level of surge protection. It utilizes multiple layers of protection, including its unique automatic voltage monitoring technology. This feature continuously monitors incoming voltage levels, automatically disconnecting the power when it detects a significant surge or drop. This ensures that valuable electronics are well protected from potentially damaging power spikes.

The 7500-PRO includes a total of 11 outlets, divided into both controlled and continuously-on configurations. This allows users to manage their devices effectively, prioritizing essential electronics while providing versatility for other equipment. Of the 11 outlets, four are specifically designed for high-current applications, ideal for audio/video components that require more power.

In terms of connectivity, the Panamax 7500-PRO features both coaxial and Ethernet surge protection. This is a crucial addition, considering the increasing reliance on network connections for streaming and gaming. The integrated network protection ensures that devices connected to the internet are shielded from surges that may occur through data lines.

Another essential aspect of the 7500-PRO is its PureFilter technology. This innovative filtering system significantly reduces noise and interference from the power line, resulting in cleaner power delivery. This is particularly beneficial for audiophiles and video enthusiasts, as it enhances the overall performance and clarity of their equipment.

The product also boasts a sleek, modern design, making it a fitting addition to any home theater or workspace. Its rack-mountable configuration caters to professional installations, adding to its appeal among audiophiles and those in similar fields.

In summary, the Panamax 7500-PRO stands out for its comprehensive protection features, including automatic voltage monitoring, network surge protection, and superior filtering technology. Its practical design and versatile outlet configuration make it an excellent choice for anyone seeking to protect their electronic investments while enhancing performance. Whether for home use or professional settings, the Panamax 7500-PRO is a reliable solution for power management and protection.