MAX PRO-SERIES Communication/Configuration Specifications (continued)

QUERIES

Query

 

Description

Response

2.1

?ID<CR>

Request that the unit identify itself.

$PANAMAX<CR>

 

 

 

$MAX 74/7500-PRO<CR>

 

 

 

$FIRMWARE revision<CR>

 

 

 

 

2.2

?TRIGSTAT<CR>

Request the on/off status of the front panel

if front panel button is ON, $BUTTON = ON<CR>

 

 

button and input trigger.

if front panel button is OFF, $BUTTON = OFF<CR>

 

 

 

 

 

 

if input trigger is ON, $TRIGIN = ON<CR>

 

 

 

if trigger input is OFF, $TRIGIN = OFF<CR>

 

 

 

 

2.3

?OUTLETSTAT<CR>

Request the on/off status of the

$BANK1 = status<CR>

 

 

outlet banks and output trigger.

$BANK2 = status<CR>

 

 

 

 

 

 

$BANK3 = status<CR>

 

 

 

$BANK4 = status<CR>

 

 

 

$HC1 = status<CR>

 

 

 

$HC2 = status<CR>

 

 

 

$TRIGOUT = status<CR>

 

 

 

status = { ON, OFF }

 

 

 

 

2.4

?POWERSTAT<CR>

Request the status of the input voltage.

if input voltage is within limits, $PWR = NORMAL<CR>

 

 

 

during overvoltage, $PWR = OVERVOLTAGE<CR>

 

 

 

during undervoltage, $PWR = UNDERVOLTAGE<CR>

 

 

 

during recovery, $PWR = RECOVERY<CR>

 

 

 

 

2.5

?VOLTAGE<CR>

Request the line voltage.

If 140V > Vin > 90: $VOLTAGE = xxx<CR>

 

 

 

where xxx is the input line voltage expressed in decimal format. If the

 

 

 

voltage is less than 100, the hundreds digit is represented with a 0.

 

 

 

For example, a line voltage of 92VAC would be expressed as:

 

 

 

$VOLTAGE = 092<CR>

 

 

 

If Vin > 140V: $VOLTAGE = OVERVOLTAGE

 

 

 

If Vin < 90V: $VOLTAGE = UNDERVOLTAGE

 

 

 

 

2.6

?CURRENT<CR>

Request the input current draw.

$CURRENT = xxx<CR>

 

 

 

where xxx is the input current expressed in decimal format. If the cur-

 

 

 

rent is less than 10, the tens digit is represented with a 0. For example,

 

 

 

a current of 3.3A would be expressed as:

 

 

 

$CURRENT = 03.3<CR>

 

 

 

 

2.7

?HELP<CR>

Request a list of all commands

Transmit a listing of all commands and queries.

 

 

and queries.

 

 

 

 

 