FEATURE OVERVIEW
1.Power Switch
Pushbutton; activates a turn-on or turn-off sequence for all outlets when depressed for two seconds.
2.Bank Status Indicators:
When on, indicates that the corresponding bank is on.
When off, indicates the corre- sponding bank is off.
When flashing, indicates the bank is in transition, either turning on or turning off.
3.Ground Isolation:
Controls the ground connec- tion of banks 3 and 4.
When active these banks have Balanced Power with an isolated ground connection.
When not active these banks have Balance Power with a common ground reference.
5. Voltmeter:
Backlit analog meter displays the incoming voltage between 90-140 VAC.
Integrated “Unsafe Voltage” indicator will flash after sensing an unsafe voltage and disconnecting all outlets.
Integrated “Out of Regulation” indicator will flash whenever the regulated output voltage is out of spec.
6. Combination Meter: | 7. Ambient |
Displays the regulated output voltage, | Light Sensor |
90-140 VAC in one mode. Displays | |
the Input Current draw, 1-15 Amps, | |
in the alternate mode. | |
| | | BRIGHTNESS |
BANK 5 | BANK 5 | | |
| | | AUTO |
HC 1 ON | HC 2 ON | | |
HIGH CURRENT | GROUND | PRESS: |
| | ISOLATION | METER SELECT |
ACTIVE
HomeTheater Power Management
4. Brightness Control/Meter Select:
When in the full/locked left position, auto brightness is engaged, and the front panel display will dim with the ambient light level. Rotating the knob to the right will increase the display brightness, and left will decrease the display brightness.
Pressing this control will toggle the display of the second meter from “Volts Out” to “Amps In”.
8:Convenience Outlet:
Provides a quick convenient way to plug in components such as cam- corders and video game systems.
1. 15A Main Circuit | 2. Filtered Regulated | 3. Isolated (Switched) | 4. High Current Outlet | 5. Isolated Outlets | 6. Satellite Coax Jacks: | 8. Settings Option: Two- |
Breaker: Opens in the | Outlets (BANKS 1 & 2): | Outlets (BANKS 3 & 4): | Bank (BANK 5): Two | Circuit Breaker: | Two pairs of F-Connectors | position slide switch. Switch |
event that equipment | Four, Balanced Double L fil- | Four outlets provide complete | delayed outlets designed | Opens in the event that | optimized for Satellite TV | settings selects the use of the |
plugged into the MAX | tered outlets for low current | isolation for digital source | for high current compo- | equipment connected to | signal line protection. | five switches to configure the |
7500 draws too much | analog audio components | components such as DVD | nents such as amplifiers | the Isolation Transformer | Bi-directional | outlets for delayed or always- |
current. When white is | such as pre-amplifiers, | players or display devices like | and powered subwoofers. | Outlets exceeds 6 Amps | | on operation. Custom settings |
visible, the breaker has | receivers, VCR's and tape | plasma TVs or DLP | The current available to | current draw. When white | 7. CATV Coax Jacks: | selects the stored configuration |
opened. Reduce the | decks. | projectors. These outlets are | connected equipment is | is visible, the breaker has | One pair of F-Connectors | in non-volatile memory for the |
load and push to reset. | | | | completely isolated from the | not limited by the noise | opened. Reduce the load | optimized for Cable TV, | outlets trigger source and |
| | | | rest of the system. | filtration components. | and push to reset. | Antenna or Cable Modem | delays. See Page 10-15 for |
| | | | | | | | signal line protection. | details. |
| | | | | | | |
| | | | | | | | Bi-directional | |
| | | | | | | | |
15 AMP CIRCUIT BREAKER | BANK 1 ALWAYS ON | BANK 2 SWITCHED | BANK 3 SWITCHED | | BANK 4 SWITCHED | | BANK 5 HIGH CURRENT | | | | | | | | | | | | | |
| | | | | | | REGULATED & ISOLATED FOR HD VIDEO | | | | | | | | | | HD | | | | | | HD | | |
| | | | | | | MONTHLY | | SEEINSTRUCTIOS | | | | | | SATELLITE | | | | | CATV / ANT | | |
| | | | | MONTHLY | | | | | | | SATELLITE 1 | | SATELLITE 2 | | CABLE 1 | | | CABLE 2 | |
| | | | | | | | | CIRCUIT BREAKER | | | | | | | | | | | | |
| | | | | | | | | BANKS 3 AND 4 | | | | | | | | | | | | | |
GROUND | | | | | TEST | RESET | TEST | RESET | | | HC 1 | | | | | | | | | | | | | |
LUG | | | | | | | | | | | | | | | | | | | |
| | | | DVR & | | | | | | | SWITCHED | | | | | | | | | | | | | |
| HD CABLE | | | | | | | SUB | | | | | | | | | | | | | | SWITCH | |
| REGULATED | DIGITAL | | | | | | RECEIVER | | ALWAYS | ALWAYS | | ALWAYS | | ALWAYS | ALWAYS | |
| HD SAT | | | | | AMP | | | | SETTINGS | |
MAIN POWER 120VAC/15A | | | RADIO | TEST | RESET | TEST | RESET | HC 2 | | ON | DELAY | ON | DELAY | ON | DELAY | ON | DELAY | ON | DELAY | |
| | | | | | | |
| | | | | | SEEINSTRUCTIOS | | | | | SWITCHED | | | | | | | | | | | | | COMMUNICATIONINTERFACE |
| | | | | | | | | | TRIGGER | BANK 2 | BANK 3 | BANK 4 | 5 HC 1 | | 5 HC 2 | CUSTOM |
| | | | | | TEST | | | | | | | | | LAN | | PHONE | | PHONE LINE | PHONE LINE |
| | | | | TEST | | | | INPUT | OUTPUT | | LAN | | | | SETTINGS |
| | | | | | | | | LINE IN | | TO EQUIP | | LINE IN | | TO EQUIP 1 | | TO EQUIP 2 | |
| | | | | | | | 3-24VDC | 12V/400mA | | | | | | | | | | | USB LIGHT |
| | | | | | | | | | | | | | | | | | | | 5VDC/100mA |
| | | | | | | | | | | | | | | | | | | | |
| | 12 AMP MAX | | | 6 AMP MAX | | | 6 AMP MAX | | | 15 AMP MAX | | | | | | | | | | | | | |
9.IEC Main Power Receptacle:
Detachable power cord connects to this recep- tacle.
10.Ground Lug: Provides a common grounding point for equipment with separate ground leads
11.DC Trigger Input:
3.5mm (1/8”) Mini-Plug jack. Connect to a remote trigger device that uses a DC voltage signal to initiate a startup/shut- down sequence.
12.DC Trigger Output: 3.5mm (1/8”) Mini-Plug jack. The M7500-Pro generates its own 12VDC trigger to control another device.
14. LAN:
In/Out connections for Ethernet.
13.Outlet Delay Switches:
Two-position slide switches. Allows for the user to configure each bank for delayed turn-on/turn-off or always-on operation.
15.Telephone Jacks:
1In & 2 Out connections for telephone line or pay-per-view line protection.
16.Lamp Receptacle: USB jack. The convenience lamp included with the M7500- Pro is to illuminate the rear panels of other com- ponents during setup.
17.Communications Interface: RS232 interface for custom con- figuration and/or home automation control. Contact Panamax for availability of alternate TCP/IP interface.