Panamax 7500-PRO owner manual Query, Message, ?Listconfigcr

Models: 7500-PRO

1 17
Download 17 pages 61.64 Kb
Page 15
Image 15

MAX PRO-SERIES Communication/Configuration Specifications (continued)

QUERIES (continued)

Query

2.8?LIST_CONFIG<CR>

Description

Request a list of all configurable parameters and current settings.

Response

$TRIGGER FOR 1 = triggersource<CR> $TRIGGER FOR 2 = triggersource<CR> $TRIGGER FOR 3 =triggersource<CR> $TRIGGER FOR 4 = triggersource<CR> $TRIGGER FOR HC1 = triggersource<CR> $TRIGGER FOR HC2 = triggersource<CR> $TRIGGER FOR TRIGOUT = triggersource<CR> $DELAY FOR 1 = ondelay offdelay<CR> $DELAY FOR 2 = ondelay offdelay<CR> $DELAY FOR 3 = ondelay offdelay<CR> $DELAY FOR 4 = ondelay offdelay<CR> $DELAY FOR HC1 = ondelay offdelay<CR> $DELAY FOR HC2 = ondelay offdelay<CR> $DELAY FOR TRIGOUT = ondelay offdelay<CR> $BRIGHTNESS = x<CR>

$FEEDBACK = x<CR> $LINEFEED = x<CR>

RESPONSES AND WARNING MESSAGES

If unsolicited feedback is enabled, the following warning messages will be transmitted under the conditions outlined in their description.

Condition

 

Message

3.1

Outlet bank or trigger output

$BANK1 = status<CR>

 

changes (on/off) state.

$BANK2 = status<CR>

 

 

 

 

$BANK3 = status<CR>

 

 

$BANK4 = status<CR>

 

 

$HC1 = status<CR>

 

 

$HC2 = status<CR>

 

 

$TRIGOUT = status<CR>

 

 

status = { ON, OFF }

 

 

 

3.2

When either the front panel but-

if front panel button is ON, $BUTTON = ON<CR>

 

ton or input trigger (on/off) sta-

if front panel button is OFF, $BUTTON = OFF<CR>

 

tus changes, a status message is

 

sent to the controller.

if input trigger is ON, $TRIGIN = ON<CR>

 

 

 

 

if trigger input is OFF, $TRIGIN = OFF<CR>

 

 

 

3.3

Input voltage rises above the

$PWR = OVERVOLTAGE<CR>

 

overvoltage threshold.

 

 

 

 

 

 

 

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

 

13

Page 15
Image 15
Panamax 7500-PRO owner manual Query, Message, ?Listconfigcr