Chapter 3: AT Commands Reference

Table 3-146: Profile Parameters (Cont.)

 

 

 

 

 

Profile

Description

Parameter

Default

Length in

Parameter

Range

Value

Bits

 

 

 

 

 

 

 

 

 

 

 

AT&C

Set circuit 109 (DCD) behavior

0-2

1

2

 

 

 

 

 

AT&D

Set circuit 109 (DTR) behavior

0-4

2

3

 

 

 

 

 

AT&K

Flow control

0, 3-6

3

3

 

 

 

 

 

AT&Y

Power-up profile

0-1

0

1

 

 

 

 

 

S0

Auto-answer

0-255

0

8

 

 

 

 

 

S2

Escape code character

0-255

43

8

 

 

 

 

 

S3

Carriage return character

0-127

13

7

 

 

 

 

 

S4

Line feed character

0-127

10

7

 

 

 

 

 

S5

Backspace character

0-32

8

6

 

 

 

 

 

S7

Wait time for carrier. Register S7 tells the data

1-255

30

8

 

adaptor how many seconds to wait for a

 

 

 

 

remote data adaptor's carrier signal before

 

 

 

 

hanging up. The register value can be

 

 

 

 

increased if the data adaptor does not detect a

 

 

 

 

carrier within the specified time. If the data

 

 

 

 

adaptor detects a remote carrier signal within

 

 

 

 

the specified time, it sends a CONNECT

 

 

 

 

response and enters Data mode. If it does not

 

 

 

 

detect a remote carrier signal within the speci-

 

 

 

 

fied time, it sends the NO ANSWER (or 8)

 

 

 

 

response, hangs up, and returns to the Com-

 

 

 

 

mand Mode.

 

 

 

 

 

 

 

 

S 12

Time, in 50ths of a second, until OK is dis-

0-255

20

8

 

played after entering command mode by an

 

 

 

 

escape sequence.

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

AT&W0

OK

AT&W1

OK

April 15, 2008

G24-L AT Commands Reference Manual

3-223

Page 287
Image 287
PIONEERPOS G24-LC manual At&C, At&D, At&K, At&Y, April 15 G24-L AT Commands Reference Manual 223