OK

+MBC, Battery Charger

This command allows the battery charger to be managed (start, stop or automatic manage) and get indication for the battery level (solicited or unsolicited reports).

The Battery is external to the G24-L and connected via the 70 pin connector.

The values of the battery are: 3.2V-4.2V divided to 5 battery levels.

Notes:

When the battery level is below the minimum, the G24-L will not power up untill the pre-chargelevel reaches the minimum level for activation.

The G24-L will manage the charging process and algorithm when charging is enabled.

The unsolicited reports will appear in the following cases (in case <Ind=1>):

1.Each time the level of the battery changes.

2.Inside the limits (3.2 and 4.2).

3.Charger connected/disconnected.

The unsolicited report will appear even if the charger cable is not connected (only in case of <Ind=1>).

ERRORS: Trying to start a charging process without a battery, error message of: NO BATTERY DETECTION will be received, for any other problems the following will be received: ERROR IN CHARGING PROCESS.

 

 

 

 

Command

Syntax

Response/Action

Remarks

Type

 

 

 

 

 

 

 

 

Set

AT+MBC=<Mode>,<

OK

The Set command sets the different

 

Ind >

or:

mode (start, stop or automatic) and

 

 

+CME ERROR: <err>

sets the report to be solicited or

 

 

 

unsolicited.

 

 

 

 

Read

AT+MBC?

+MBC:

The Read command returns the current

 

 

<Status>,<Batterylevel

status, battery level, mode and

 

 

>,<Mode>,<Ind>

indication.

 

 

OK

 

 

 

 

 

Test

AT+MBC=?

+MBC: (List of

The Test command returns the list of

 

 

supported Mode),(List

supported modes and indications.

 

 

of supported

 

 

 

Indication)

 

 

 

OK

 

 

 

 

 

 

 

 

 

3-130