Hardware Information

Table 3-98: +MMAD Parameters (Cont.)

 

 

 

<Parameter>

Description

Range/Remark

 

 

 

 

 

 

<Report_interv

0 - 255 Time interval between two averages reports (seconds).

0 - Default value.

al>

 

 

 

 

 

<Average>

Average calculation result.

 

 

 

 

 

 

 

Example

AT+MMAD =1

// Read A2D1 values with analog input of 1.75V.

+MMAD:1,175

 

OK

 

AT+MMAD=2,1,15

// Read A2D2 converted value every 15 seconds and send

OK

// unsolicited report to the DTE.

+MMAD: 2, 10

// Unsolicited Report after 15 seconds.

+MMAD: 2, 12

// Unsolicited Report after 30 seconds.

AT+MMAD= 3, 2,1,25,100

// Read A2D3 converted value every 1 second and send

OK

// unsolicited report if the converted value is out of boundaries.

+MMAD: 3,102

// Unsolicited report of value out of boundaries.

:

 

minutes, rate=5.

// Activate Average calcluation periodically every 30 sec, during 5

 

 

// report originated by G24

duration=5

// Converter num=1, report=3, rate=5*100ms, low,high, N_samples,

 

AT+MMAD =1,3,5, , ,16,5,30

 

OK

 

+MMAD:1,175

//First report

+MMAD:1,140

//Second report

…..

 

+MMAD:1,160

//Last Avr report

AT+MMAD =1,0,5, , ,16,5,0

// Activate Average calcluation during 5 minutes, rate=5.

duration=5 min

// Converter num=1, report=0, rate=5*100ms, low,high, 16,

 

OK

 

AT+MMAD=1

//Only on explicit “AT+MMAD=<Converter_number>” command

OK

 

3-152

G24-L AT Commands Reference Manual

April 15, 2008

Page 216
Image 216
PIONEERPOS G24-LC manual Parameter Description Range/Remark Reportinterv, Average, AT+MMAD =1, AT+MMAD=1