Rinnai IB35ETRN, IB35ETRLC installation manual Error Codes, Error code, Probable cause, Comments

Models: IB35ETRN IB35ETRLC

1 32
Download 32 pages 19.04 Kb
Page 23
Image 23
ERROR CODES

ERROR CODES

• ERROR CODE MESSAGE

The Flame Fire ETR has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on the Digital Display of the control panel. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service.

Error code

Probable cause

Comments

11

Ignition failure

Check gas is turned on.

Service call if repeated

 

 

12

Flame failure

Check gas is turned on.

Service call if repeated

 

 

14

Overheat

Service call

 

 

 

16

Room overheat

Lower rom temperaure to

less than 104°F

 

 

31

Room temperature sensor faulty

Service call

 

 

32

Service call

 

 

 

 

33

Overheat temperature sensor faulty

Service call

 

 

 

70

faulty ON / OFF switch

Service call

 

 

 

71

Faulty soleniods

Service call

 

 

 

72

Faulty flame rod

Service call

 

 

 

73

Communication error

Service call

 

 

 

99

Flue block

Service call

 

 

 

--:--

Power failure

Service call

 

 

 

In all cases, you may be able to clear the Error Message simply by turning the unit OFF, then ON again. If the Error Message still remains or returns on the next operation, please contact your nearest service contact and arrange for a service call.