Rinnai IB35ETRLC, IB35ETRN Wiring Diagram-Ladder, Trouble Shooting, Symptom, Cause, Solution

Models: IB35ETRN IB35ETRLC

1 32
Download 32 pages 19.04 Kb
Page 22
Image 22
WIRING DIAGRAM-LADDER

WIRING DIAGRAM-LADDER

TROUBLE SHOOTING

SYMPTOM

CAUSE

SOLUTION

 

No power present

Ensure power cord is plugged in and turned on

 

No gas present

Ensure gas supply is turned on

Burner will not light

power cut

Re-ignite after power is restored

 

Air in gas pipe

Purge air (installer)

 

Ignition failure

Repeat lighting procedure.

Smell of gas

Leaking gas

Turn gas off at meter and call installer

Fan not working

Heater still warming up

The fan is programmed to start after the heater has

 

been operating for 4 minutes.

 

 

Fan does not stop

Heater cooling down

The fan is programmed to continue running for 4

minutes after the burners have been extinguished

 

 

Small soot deposit

Normal operation

No action required

Soot deposit forming on

Inadequate flue system

Call service department/agent

glass or logs

Log misalignment

Incorrect gas pressure

 

 

 

Condensation on glass

Normal operation

Allow fire to warm up

Streaky lines on glass

Normal operation

Remove and clean glass

Digital error message on

Electronic fault detected

Refer Error Messages page 23

control panel

 

 

NOTE:

If you have any other faults or problems, please refer to your Installer or local qualified service agency

22

Page 22
Image 22
Rinnai IB35ETRLC, IB35ETRN Wiring Diagram-Ladder, Trouble Shooting, Symptom, Cause, Solution, Refer Error Messages page