VANGUARD 6000 BTU
NATURAL GAS HEATER
TROUBLESHOOTING
Note: All troubleshooting items are listed in order of operation.
WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
When ignitor button is pressed, there is no | 1. | Ignitor cable pinched or wet | 1. | Free ignitor cable if pinched by any |
spark at ODS/pilot |
|
|
| metal or tubing. Keep ignitor cable dry |
| 2. | Ignitor electrode not connected to igni- | 2. | Reconnect ignitor cable |
|
| tor cable |
|
|
| 3. | Piezo ignitor nut is loose | 3. | Tighten nut holding piezo ignitor to |
|
|
|
| heater cabinet. Nut is located inside |
|
|
|
| heater cabinet at top |
| 4. | Broken ignitor cable | 4. | Replace ignitor cable |
| 5. | Ignitor electrode broken | 5. | Replace ignitor |
| 6. | Bad piezo ignitor | 6. | Replace piezo ignitor |
| 7. | Ignitor electrode positioned wrong | 7. | Replace ignitor |
|
|
|
|
|
When ignitor button is pressed, there is | 1. | Gas supply turned off or manual shutoff | 1. | Turn on gas supply or open manual |
spark at ODS/pilot but no ignition |
| valve closed |
| shutoff valve |
| 2. | Control knob not in PILOT position | 2. | Turn control knob to PILOT position |
| 3. | Control knob not pressed in while in PI- | 3. | Press in control knob while in PILOT |
|
| LOT position |
| position |
| 4. | Air in gas lines when installed | 4. | Continue holding down control knob. |
|
|
|
| Repeat igniting operation until air is re- |
|
|
|
| moved |
| 5. | ODS/pilot is clogged | 5. | Clean ODS/pilot (see Cleaning and |
|
|
|
| Maintenance, page 11) or replace ODS/ |
|
|
|
| pilot assembly |
| 6. | Gas regulator setting is not correct | 6. | Replace gas regulator |
|
|
|
|
|
ODS/pilot lights but flame goes out when | 1. | Control knob not fully pressed in | 1. | Press in control knob fully |
control knob is released | 2. | Control knob not pressed in long enough | 2. | After ODS/pilot lights, keep control |
|
|
|
| knob pressed in 30 seconds |
| 3. | Manual shutoff valve not fully open | 3. | Fully open manual |
| 4. | Thermocouple connection loose at con- | 4. | Hand tighten until snug, then tighten 1/4 |
|
| trol valve |
| turn more |
| 5. | Pilot flame not touching thermocouple, | 5. | A) Contact local natural gas company |
|
| which allows thermocouple to cool, |
|
|
|
| causing pilot flame to go out. This prob- |
| B) Clean ODS/pilot (see Cleaning and |
|
| lem could be caused by one or both of |
| Maintenance, page 11) or replace ODS/ |
|
| the following: |
| pilot assembly |
|
| A) Low gas pressure |
|
|
|
| B) Dirty or partially clogged ODS/ |
|
|
|
| pilot |
|
|
| 6. | Thermocouple damaged | 6. | Replace thermocouple |
| 7. | Control valve damaged | 7. | Replace control valve |
Continued
12 | 103113 |