Desa BLUE FLAME VENT-FREE NATURAL GAS HEATER Inspecting Burner, Cleaning And Maintenance, Cabinet

Models: BLUE FLAME VENT-FREE NATURAL GAS HEATER

1 20
Download 20 pages 51.89 Kb
Page 11
Image 11
INSPECTING

OWNER’S MANUAL

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pat- tern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Pilot Burner

Thermocouple

GOOD PILOT

GRH/OV 009

Figure 17 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

BAD PILOT/LP

GRH/OV 008

Figure 18 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 18

BURNER FLAME PATTERN

Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

PILOT FLAME PATTERN WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If burner flame pat- tern shows yellow tipping, follow instructions at bottom of this page.

NOTICE: Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame.

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 19 - Correct Burner Flame Pattern

Yellow BURNER FLAME PATTERNTipping

CLEANING AND MAINTENANCE

CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning.

ODS/PILOT AND BURNER ORIFICE CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER ORIFICE

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

turn heater off (see To Turn Off Gas to Appliance, page 10)

see Troubleshooting, pages 12 through 14

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 20 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 10)

see Troubleshooting, pages 12 through 14

103113

11

Page 11
Image 11