Desa BLUE FLAME VENT-FREE NATURAL GAS HEATER Checking Gas Connections, Operating Heater

Models: BLUE FLAME VENT-FREE NATURAL GAS HEATER

1 20
Download 20 pages 51.89 Kb
Page 9
Image 9
CHECKING GAS CONNECTIONS

OWNER’S MANUAL

CHECKING GAS CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

Test Pressures In Excess Of 1/2 WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2

PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 13).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to manual shutoff valve (see Figure 14). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING

HEATER GAS

CONNECTIONS

1.Open manual shutoff valve (see Figure 13).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 14). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 9 and 10). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas To Appliance, page 10).

8.Replace front panel.

Open

Manual

Shutoff

Valve

Closed

Figure 13 - Manual Shutoff Valve

Control Valve Location

Gas Meter

Manual

Shutoff

Test Pressures Equal To or Less Than 1/2 PSIGPRESSURE TESTING Valve

Figure 14 - Checking Gas Joints

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

OPERATING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions ex- actly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your build- ing.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

103113

9

Page 9
Image 9
Desa BLUE FLAME VENT-FREE NATURAL GAS HEATER installation manual Checking Gas Connections, Operating Heater, Owner’S Manual