proceed to TIMER 2 - which is programmed in the same way - or three times to return to the clock display. This must be done within 1 minute of setting the time to lock it into the memory.

The digital display will show the current time. A small indicator on the digital display will flash to show that the display has returned to the clock.

After setting timer 2 the SET TIMES button must be pressed once within one minute of programming to lock in the times and return to the clock display.

The timers operate over a 24 hour period, and will activate 7 days a week when set.

OPERATING THE TIMERS

Before operating the timer(s), the clock time must be correct and a starting time and finishing time for the timer(s) must be programmed, see page 9. Both timers operate in the same way.

Ignite the heater and select the preset temperature as for normal operation.

Press the timer 1 and / or timer 2 button(s). The timer indicator(s) will glow and the unit will change to stand-by mode. The burners will extinguish and the ON indicator will change from red to green. The display will show the start time for the selected timer briefly before returning to the clock display.

When the heater is in stand-bys mode, you can display and change the clock and the on and off times for both timers in the same way as described earlier.

The timers can be deactivated by either pressing the timer button(s) that you want to deactivate or by turning the heater off using the ON/OFF button.

NOTE: If there is a power failure, the system memory will retain the Timer programs, and the clock will stop at the time the power goes off. The clock will start

again when the power comes back on, but the time will be slow by the duration of the power failure. To set the clock to the correct time after the power has come back on, simply follow the instructions on page 9.

OVERRIDE

This function is intended to be used to manually override the current operation of the heater. For example; If the heater is in stand-by mode (ie. between finishing time and starting time of a timer), and the OVERRIDE button is selected, then the heater will begin to operate and heat the room.

Press the OVERRIDE button to activate. The indicator light will flash when active.

To manually deactivate the OVERRIDE press the OVERRIDE button again. The OVERRIDE indicator will go out, and the heater will return to stand-by mode.

The heater will continue to operate on OVERRIDE until the OVERRIDE button is pressed again, or one of the timers takes over the operation of the heater. This means that the OVERRIDE mode will automatically turn off if a programmed starting time is reached. The heater will then return to operating at times programmed into the timer(s). Turning the heater off will also deactivate the

OVERRIDE.

REMOTE CONTROL

The remote control can only be used for manual operation of the heater. If the heater is in stand-by (timer) mode then only the OFF button will work. Pressing the OFF button when the heater is in stand-by mode will deactivate the timers and the heater can now be operated manually.

The ON and OFF buttons on the remote work in the same way as the ON / OFF button on the control panel as do the “

“ and “

“ buttons.

11

Page 11
Image 11
Rinnai IB35ETRN, IB35ETRLC installation manual Operating the Timers, Override, Remote Control

IB35ETRN, IB35ETRLC specifications

The Rinnai IB35ETRN and IB35ETRLC are advanced, energy-efficient heating solutions designed for residential and light commercial applications. These models belong to Rinnai's innovative range of condensing boilers, delivering exceptional performance while maximizing fuel efficiency.

One of the primary features of the Rinnai IB35ETRN and IB35ETRLC is their compact design. Both models are engineered to fit seamlessly into a variety of spaces, making them ideal for homes where space is at a premium. Their sleek, modern aesthetic complements contemporary décor, providing a discreet heating solution that does not compromise on performance.

The IB35ETRN and IB35ETRLC utilize cutting-edge condensing technology, which captures and reuses exhaust gases to enhance efficiency. This feature allows the boilers to achieve an impressive annual fuel utilization efficiency (AFUE) rating, making them not only environmentally friendly but also cost-effective in terms of energy consumption. Homeowners can appreciate reduced utility bills while maintaining comfortable indoor temperatures.

Another significant characteristic of these models is their modulating heating capacity. Both units can adjust their output based on the heating demands of the space, ensuring optimal comfort without unnecessary energy waste. This modulation capability means that the units can operate efficiently even in varying weather conditions, providing reliable warmth throughout the year.

The Rinnai IB35ETRN and IB35ETRLC are also designed with user-friendly interfaces that allow for easy operation and monitoring. Features such as programmable thermostats enable homeowners to set desired temperatures for different times of the day, further enhancing energy savings. The intuitive control systems provide clear displays of performance metrics, making it simple to manage heating requirements.

Safety and reliability are paramount, and both models are equipped with several protective features, including overload protection and automatic shutoff in the event of an issue. This technology ensures the safety of the home and adds peace of mind for users.

In summary, the Rinnai IB35ETRN and IB35ETRLC are state-of-the-art heating solutions that combine efficiency, compact design, and advanced technology. With their impressive AFUE ratings and modulating heating capacities, these models are ideal for those seeking reliable, energy-efficient heating systems for their homes or light commercial spaces. Rinnai's commitment to quality and innovation positions these boilers as top choices in today's market.