Audio

The following table shows the S94 parameters.

Table 3-105: S94 Parameters

 

 

 

<Parameter>

 

Description

 

 

 

 

 

 

<n>

0

Disable sidetone

 

1

Enable sidetone

 

On power up the sidetone is enabled.

 

 

 

 

 

 

Example

ATS94=0

//Disable sidetone

OK

 

ATS94=2

 

+CME ERROR: <err>

 

ATS94?

 

000

//Sidetone disabled

OK

 

S96, Echo Canceling

This command suppresses a large amount of the output sound picked up by the input device (cancels all echo). S96 value is saved in the Flex.

The following table explains the use of the ATS96 set.

Table 3-106: ATS96 and ATS94 Behavior

 

 

 

 

 

 

 

 

 

 

ATS96

ATS94

Echo Cancel

 

Noise Suppress

ST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

Disabled

 

Disabled

Disabled

 

 

 

 

 

 

 

 

 

 

0

1

 

Disabled

 

Disabled

Enabled

 

 

 

 

 

 

 

 

 

 

1

0

 

Enabled

 

Enabled

Disabled

 

 

 

 

 

 

 

 

 

 

1

1

 

Enabled

 

Enabled

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Type

Syntax

 

Response/Action

 

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

ATS96=<n>

 

OK

 

The Set command sets the echo

 

 

 

 

or:

 

canceling and noise suppression status.

 

 

 

 

+CME ERROR: <err>

 

 

 

 

 

 

 

 

 

 

Read

ATS96?

 

<000-disabled,

 

The Read command returns the echo

 

 

 

 

001-enabled>

 

canceling and noise suppression status.

 

 

 

 

OK

 

 

 

 

 

 

 

or:

 

 

 

 

 

 

 

+CME ERROR: <err>

 

 

 

 

 

 

 

 

 

 

Test

ATS96=?

 

+CME ERROR: <err>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-162

G24-L AT Commands Reference Manual

April 15, 2008

Page 226
Image 226
PIONEERPOS G24-LC manual S96, Echo Canceling, 105 S94 Parameters, 106 ATS96 and ATS94 Behavior, ATS96 ATS94